Installation instructions

3.5.1 Electrical connection

Information about electrical connections is available on the machine's wiring
diagram which is provided on delivery. Store the diagrams in the plastic pocket,
located in the electrical cabinet, even after installation.
After completing the installation, switch on the main switch and all circuit
breakers.

3.5.2 Water connection, regardless of any options

The water pipe is connected at (2) or at (7). If the machine is connected with a
hose, this should be steel braided and have an internal diameter of at least 12
mm.
The hot water connection on the machine is fitted with a filter.
As the machine is fitted with a "Break Tank", the connection is fitted with a filter
and non-return valve.
WD-8
The machine is designed for quick electrical installation.
The machine must be connected to a lockable power switch. This should
be placed on a wall, well-protected from water and from the steam which
escapes when the machine is opened. The machine is supplied with the
electrical cable connected (1).
A shut-off cock must be installed on the incoming pipe.
It is important that the water supply has sufficient pressure to ensure the
correct flow of water to the machine. The required water flow and pressure
can be found in the TECHNICAL SPECIFICATIONS. If the water pressure
is too low, a booster pump must be fitted.