Detergent And Drying Agent Connection - Wexiodisk WD-6 Installation And User Manual

Hood type dishwasher
Table of Contents

Advertisement

Installation

3.5.10 Detergent and drying agent connection

Drying agent equipment is included with the machine. Connect the suction hose
on the drying agent injector to the drying agent container.
The equipment for liquid detergent is option. If the machine is supplied with deter-
gent equipment, connect the suction hose on the detergent pump to the detergent
container.
If equipment for a different type of detergent is used, it should preferably be put
on the wall behind the machine to avoid holes being drilled unnecessarily in the
machine.
There is a plugged hole for a detergent hose on the back and end of the machine
(4). The holes must be fitted with edge strips or similar protection.
The detergent hose is connected to the pipe (A) at the top of the chemical wash-
ing tank on the right-hand side (see the figure below). There is a connection nipple
in the pipe (B).
If detergent paste is being used, the connection nipple must be removed and the
hose connected directly to the pipe (A).
If liquid detergent is used, the nipple must be left in the pipe. Drill a hole through
the nipple and connect the hose to the nipple.
The measuring cell for measuring the concentration of detergent in the washing
water must be put in the bottom of the tank. On the inside bottom of the tank next
to the heating element, the letter "C" is stamped into the metal to mark where the
hole should be drilled. If holes need to be made in the machine, each hole must
be fitted with an edge strip or similar protection.
Connecting the detergent hose
Marking for measuring cell
The water outlet for detergent (6) is on the incoming water pipe (2).
The process of setting the detergent and drying agent dosage is described in the
ADJUSTMENT INSTRUCTIONS.
Electrical connections, see wiring diagram.
The machine can also be equipped with detergent and drying agent equipment
via external connections. See the wiring diagram for the correct connection.
WD-6
A
C
6D_tank
A=Connection in the tank
B=Connection nipple
C=Marking in bottom of tank for measuring cell
19
B
Rev. 4,0 (201302)