IO configuration

The NTC-6200 Series Router is equipped with a 6-way terminal block connector providing 3 identical multipurpose inputs and
outputs as well as a dedicated ignition input. These inputs and outputs may be independently configured for various functions,
including:
NAMUR (EN 60947-5-6 / IEC 60947-5-6) compatible proximity sensor input
Proximity sensor input for use with contact closure (open/closed) type of sensors (PIR sensors, door/window sensors
for security applications) with the input tamper detection possible (four states detected: open, closed, short and break)
by the use of external resistors
Analogue 0V to 30V input
Digital input (the I/O voltage measured by the Analogue input and the software making decision about the input state)
with the threshold levels configurable in software
Open collector output.
Use the pull up voltage options to select the desired output voltage of the I/O pins. The pull up voltage you select will be the same
for each pin when pull up is enabled for that pin. Each pin is capable of outputting either 3.3V or 8.2V.
ITEM
IO configuration
IO Functionality
Pull up voltage
IO Manager Debug level
Per pin configuration
Pin
Mode
Pull up
Value
www.netcommwireless.com
Figure 97 – IO configuration options
Enables the configuration of the input and output pins on the Six-way terminal block.
Specifies the output voltage of the I/O pins.
Use the slide bar to adjust the level of detail you would like to see in the log for IO messages. A
higher debug level displays more detailed messages in the log file.
The I/O pin number corresponding to the pin on the terminal block that you wish to configure.
The mode of operation for the corresponding pin. Available options are Digital input, Digital output,
Analogue input, Namur input, Contact closure input.
Use the pull up toggle keys to turn the pull up on or off for the corresponding pin. When turned on,
the pull up voltage output is the value specified in the "Pull up voltage" option.
The value column displays whether the voltage detected on the line is low or high or allows you to
configure the output value in the case that the pin is set to digital output. This can be useful for
applications where monitoring of the transition between low and high is used to trigger an action.
Table 22 - IO configuration options