Legacy data managers
The Legacy data managers section provides the option to configure the built-in serial port to function with legacy equipment.
Note:
Modem emulator and PAD Daemon may not be configured to use an external serial port such as one connected via USB.
Because they may only use the built-in serial port, only one legacy data manager may be configured for use at any
particular time. Additionally, when one of these legacy data managers is configured, any user-created data streams
involving the built-in serial port endpoint will cause a conflict and result in all streams failing until the conflict is removed.
The priority of the built-in serial port is (from highest to lowest): Data stream endpoints, PAD Daemon, Modem emulator
Modem emulator
Modem emulator allows you to connect legacy equipment such as an RTU or PLC to the serial port of the router in place of a
traditional dial-up modem. The NTC-6200 series router emulates the dial-up modem's behaviour and passes the serial data over
the IP network.