98
en | Device Specifications and Overview
Entering Test Mode
Place the detector in Test Mode. In Test Mode, the detector's LED disable switch (Item 8,
Figure 10.9 on Page 95) is overridden. You can enter the Test Mode locally or remotely.
To enter the Test Mode locally:
1.
2.
3.
DANGER!
The 13-332 Sound Sensor Tester produces extremely loud sounds and can be hazardous to
hearing when used at close range. Do not point the 13-332 towards someone's head.
To enter the Test Mode remotely:
1.
2.
3.
The tester buzzes and the green LED on the detector flashes once per sec. If the green LED
does not flash, move closer to the detector and repeat the procedure.
Testing
Testing the Detector (Flex and Audio Signals)
1.
2.
3.
4.
5.
If the detector receives both the flex and audio signals properly, its red Alarm LED lights for
3 sec.
If the red LED does not light, return to Section 9.0 RFSS Site Testing on page 81 to reposition
the detector.
F01U087835 | 02 | 2008.10
Carefully open the service door of the detector.
Insert a screwdriver into the slot next to the sensitivity switches that contains the test
pads (Item 1, Figure 10.9 on Page 95).
Momentarily short both test pads together with the tip of the screwdriver, or other
metallic conductive object.
The Event LED (green) (Item 6, Figure 10.9 on Page 95) flashes once per sec. If the green
LED does not flash, repeat Steps 10 and 11.
Stand within 3 m of the detector.
Move the switches on top of the 13-332 Tester to ACTIVATE and to MAN modes (Items 1
and 3, Figure 10.9 on Page 95).
Point the front of the tester towards the detector and press the red Start button on top
(Item 2, Figure 10.9 on Page 95).
Set the 13-332 Tester switches to the TEST and FLEX positions (Items 1 and 3,
Figure 10.9 on Page 95).
Press the red Start button (Item 2, Figure 10.9 on Page 95). The tester activates and
starts an eight-sec armed period.
If window coverings are present, close them fully.
Hold the 13-332 Tester near the point on the glass farthest from the detector. If window
coverings are present, hold the tester between the glass and window coverings.
Carefully strike the glass with a cushioned tool. The 13-332 Tester responds by producing
a burst of glass break audio.