Bosch ICP-EZM2 Easy Series System Reference Manual page 53

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

Easy Series
Programming Item Number
(bold digits = Point Number)
9016, 9026, 9036, 9046...
9101...9151...9201...9321
9018, 9028, 9038, 9048...
9108...9158...9208...9328
Point Type (9011 ... 9321): Point 1 = 6, Points 2 - 5 = 1, Points 6 - 8 = 2, Points 9 - 32 = 0
Circuit Style (9012 ... 9322): Points 1 - 32 = 2
Custom Protection (9013 ... 9323): Points 1 - 32 = 0
Cross Zone Enabled (9021 ... 9321): 1
Response Time (9015 ... 9085): Points 1 - 8 only = 6
Wireless Sensitivity (9018 ... 9328): Points 1 - 32 = 0
Alarm Verification (9016 ... 9326): Points 1 - 32 = 0
Table 5.3 Manuf. Default for Point Programming Items
Bosch Security Systems, Inc.
Programming Item
Alarm Verification
Wireless Detector Sensitivity
System Reference Guide
Selections
0 = Disable alarm verification
1 = Enable alarm verification
Motion Detector (PIR and dual)
0 = Standard
4 = Intermediate
Inertia Detector: Gross Attack Options
0 = Tap off, low sensitivity
1 = Tap off, low/medium sensitivity
2 = Tap off, medium/high sensitivity
3 = Tap off, high sensitivity
Inertia Detector: Minor Attack Options
8 = Tap on, 8 taps, low sensitivity
9 = Tap on, 8 taps, low/medium sensitivity
10 = Tap on, 8 taps, medium/high sensitivity
11 = Tap on, 8 taps, high sensitivity
12 = Tap on, 4 taps, low sensitivity
13 = Tap on, 4 taps, low/medium sensitivity
14 = Tap on, 4 taps, medium/high sensitivity
15 = Tap on, 4 taps, high sensitivity
Programming | en
53
F01U087835 | 02 | 2008.10