114 en | Agency Approvals and Requirements
12.3
Industry Canada
This product meets the applicable Industry Canada technical specifications.
The ringer equivalence number (REN) for this terminal equipment is 0.0. The REN assigned to
each terminal equipment indicates the maximum number of terminals allowed to be
connected to a telephone interface. The termination of an interface can consist of any
combination of devices subject only to the requirement that the sum of the REN of all devices
does not exceed five.
12.4
SIA
Programming Requirements
To comply with ANSI/SIA CP-01 False Alarm Reduction, set these programming items as
follows:
Programming Item
Intrusion Abort Window
Intrusion Cancel Window
Exit Delay
Entry Delay
Swinger Bypass Count
Auto Protection Level
To comply with ANSI/SIA CP-01 False Alarm Reduction, by default, this system:
–
–
–
F01U087835 | 02 | 2008.10
Sends Intrusion Alarm Verified and Exit Error reports
Sends a Recent Closing report for any alarm that occurs within two min of the end of Exit
Delay
Includes a Fire Verified point type option that is disabled by default
System Reference Guide
Item Number
Default
110
30 sec
112
5 min
126
60 sec
127
30 sec
131
1
132
1
Easy Series
Section Starting Page
Page 43
Bosch Security Systems, Inc.