Easy Series
5.1.4
Outputs
Output devices consist of horns, bells, strobes, or sirens.
Outputs
Enter an output number from 1 to 8
1
Set Output Function
–
Press [1] to select the current
option.
–
Press [2] to hear more options.
–
Press [#] to exit Output Function.
#
Exit Points
Return to Installer Menu.
NOTICE!
When the installer PIN is entered at the keypad or phone, a 3 sec time window starts. During
i
that time window, a tamper alarm activates the interior siren for only 1 sec. Open the
enclosure door during this time to silence the sirens during maintenance. Once the enclosure
is closed, tamper alarm is restored after a 3 min delay. Tampers are logged and reported.
WARNING!
If you modify system parameters you are responsible for maintaining the system within the
!
scope of the standard and regulations that apply to the hardware and/or the system in which
it is used. In a NF A2P compliant installation, use only NF A2P listed components, and check
that each parameter is in the authorized range.
Bosch Security Systems, Inc.
Output Functions:
–
Disabled
–
Intrusion
–
Intrusion Latching
–
Fire
–
Fire Latching
–
Intrusion and Fire
–
Intrusion and Fire Latching
–
System Reset
System Reference Guide
Programming | en
Output Functions (cont.):
–
System On
–
System Ready
–
Key Fob On/Off
–
Key Fob 2-sec Pulse
–
User Controlled
–
Interior Intrusion and Fire
–
System On (Unoccupied)
F01U087835 | 02 | 2008.10
41