Bosch ICP-EZM2 Easy Series System Reference Manual page 7

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

Easy Series
Callouts for Figure 1.2, Page 8
1
Control Center
2
wLSN Hub
DX2010 Point Expander
4
DX4020 Network Interface Module Data Bus Adr 134
5
ITS-DX4020-G
6
Supervised Points (single EOL)
7
Supervised Points (dual EOL)
Keyswitch Options (single and dual EOL) ((2.2k Ω)
8
9
Prog Output (PO) 1 Options
10 Prog Outputs 2 - 4
11 2-wire Smoke Detector Option
12 4-wire Smoke Detector Option
Note: The system uses a 12 VDC battery, connected as shown.
Bosch Security Systems, Inc.
Mount within 3 m of control panel, Use CAT5 cable (twisted pair) for audio
bus, Set data bus address (1 - 4), up to 4 controls max
S1
S2
S3
1
0
0
= Normal Operation
9
2
0
= RFSS Mode
9
8
7
= Default Hub (refer to Page 60)
Data Bus Adr 102: Points 9 - 16
Data Bus Adr 103: Points 17 - 24
Data Bus Adr 104: Points 25 - 32
Data Bus Adr 134 (Fixed)
Normally open and normally closed options (2.2k Ω)
Normally closed (2.2k Ω)
Switched 12v Switched Ground
NF A2P requires that sirens have a backup battery. When this siren
requires a 14,1V to 14,4V supply, use the optional board EZPS-FRA or the
auxiliary power supply IPP-PSU-2A5. Set the output as interior burglary
alarm.
EOL resistor (P/N: 25899) required.
EOL resistor (P/N: 25899) and Bosch EOL relay module required
System Reference Guide
Overview | en
1 - On
2 - Off
Dry Contact
F01U087835 | 02 | 2008.10
7