Control Panel Event Codes (Sia And Contact Id) - Bosch ICP-EZM2 Easy Series System Reference Manual

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

58
en | Control Panel Event Codes (SIA and Contact ID)
6

Control Panel Event Codes (SIA and Contact ID)

Event
Intrusion Alarm
Intrusion Alarm Verified
Intrusion Alarm Unverified
Intrusion Alarm 24-hr
Intrusion Alarm 24-hr Restoral
Intrusion Alarm Restoral
Duress
Exit Error
Fire Alarm
Fire Alarm Unverified
Fire Alarm Restoral
Panic
Panic Restoral
User Emergency (Medical)
User Fire
User Fire Restoral
User Panic
Cancel
Intrusion Trouble
Intrusion Trouble Restoral
Intrusion Point Bypass
Intrusion Point Bypass Restoral BU
Fire Trouble
Fire Trouble Restoral
Recent Closing
Close (System On) Unoccupied CL
Close (System On) Occupied
Close (System On) Custom
Close (System On) Partial
Close (System On) Keyswitch
Open (System Off)
Open (System Off) Keyswitch
AC Fail
AC Fail Restoral
Auto System Test (Normal)
Auto System Test (Off-Normal)
Auxiliary Power Fault
Auxiliary Power Restoral
Communication Fail
Communication Restoral
Control Center Supervision Fail EM
Control Center Supervision
Restoral
Control Center Tamper
Control Center Tamper Restoral EJ
Local Programming
Low Battery
Low Battery Restoral
Communication Test
Phone Line Fault
F01U087835 | 02 | 2008.10
SIA
Report
BA
Burglary Alarm
BV
Burglary Alarm Verified
BG
Unverified Event Burglary
BA
Burglary Alarm
BH
Burglary Alarm Restore
BR
Burglary Restoral
HA
Hold Up Alarm
EA
Exit Alarm
FA
Fire Alarm
FG
Unverified Event-Fire
FH
Fire Alarm Restore
HA
Holdup Alarm
HH
Holdup Alarm Restore
QA
Emergency Alarm
FA
Fire Alarm
FH
Fire Alarm Restore
HA
Holdup Alarm
BC
Burglary Cancel
BT
Burglary Trouble
BJ
Burglary Trouble Restore
BB
Burglary Bypass
Burglary Unbypass
FT
Fire Trouble
FJ
Fire Trouble Restore
CR
Recent Closing
Closing Report
CL
Closing Report
CL
Closing Report
CL
Closing Report
CS
Closing Keyswitch (User 255) 3 409
OP
Opening Report
OS
Opening Keyswitch (User
255)
AT
AC Trouble
AR
AC Restoral
RP
Automatic Test
RY
Test Off Normal
IA
Equipment Failure Condition 1 310
IR
Equipment Fail Restoral
YC
Communications Fail
YK
Communications Restoral
Expansion Device Missing
EN
Expansion Missing Restore
ES
Expansion Device Tamper
Expansion Device Tamper
Restore
LX
Local Programming Ended
YT
System Battery Trouble
YR
System Battery Restoral
RX
Manual Test
LT
Phone Line Trouble
System Reference Guide
Contact ID
Report
1 130
Burglary
1 139
Burglary
1 130
Burglary
1 133
24 Hour (Safe)
3 133
Restoral
3 130
Burglary
1 121
Duress
1 374
Exit Error (zone)
1 110
Fire
1 110
Fire
3 110
Fire
1 120
Panic
3 120
Panic
1 101
Personal Emergency
1 110
Fire
3 110
Fire
1 120
Panic
1 406
Cancel
1 380
Sensor Trouble
3 380
Sensor Trouble
1 570
Zone/Sensor bypass
3 570
Zone/Sensor bypass
1 373
Fire Trouble
3 373
Fire Trouble
1 459
Recent Closing
3 401
Unoccupied Arm by User
3 441
Occupied Arm by User
3 441
Custom Arm by User
3 456
Partial Arm by User
Keyswitch O/C (User 255)
1 401
O/C by User
1 409
Keyswitch O/C (User 255)
1 301
AC Loss
3 301
AC Loss
1 602
Period Test Report (User 0)
1 608
Period Test Report, System
Trouble Present
Ground Fault
3 310
Ground Fault
3 310
Failure to communicate event
3 354
Failure to communicate event
1 333
Expansion module failure
3 333
Sensor Trouble
1 341
Expansion Device Tamper
3 341
Expansion Device Tamper
1 628
Program mode exit
1 302
Low System Battery
3 302
Low System Battery
1 601
Manual trigger test report
1 351
Telco 1 fault
Bosch Security Systems, Inc.
Easy Series

Advertisement

Table of Contents
loading

Table of Contents