10.1

Control Panel

Enclosure
Dimensions (H x W x D):
Construction Material:
Environmental Considerations
Relative Humidity:
Operating Temperature:
Storage Temperature:
Protection Level
Supervised Points
On-board Hardwire:
Programmable Outputs (PO)
On-board:
PO 1 Relay Rating:
PO 2 to PO 4 Rating:
Number of...
Users:
Events:
Tokens and Key Fobs:
Phone Line
Phone line trouble voltage
Control Panel Power Requirements
F01U087835 | 02 | 2008.10
37 cm x 31.8 cm x 8.5 cm (14.5 in x 12.5 in x 3.25 in)
Cold-rolled steel, zinc seal, 0.36 mm thick (20 Ga.)
93% at 32°C 2°C (89.6°F 35.6°F)
-10°C to +49°C (14°F to +120°F)
CE: -10°C to +40°C (+14°F to +104°F)
NF A2P: -10°C +55°C (+14°F to +131°F)
-10°C to +55°C (+14°F to +131°F)
IP 30 - IK 04
8
Single or dual end-of-line (2.2 k EOL) tamper point support
Point 1 supports two-wire smoke detectors
All points support four-wire smoke detectors
Enclosure tamper input (does not reduce point capacity)
Reaction time lower than 250ms
4
PO 1 only: Configurable relay
PO 2 to PO 4: Configurable solid state
PO 4 only: Internal supervised speaker driver option
Contacts: 2 A with no jumper installed; resistive loads only; in a NF A2P
certified installation: 1 A
Output: 1.2 A with jumper installed; resistive loads only; in a NF A2P
certified installation 1 A
Operating Voltage: 30 VDC maximum
400 mA current sink
22
User 1: Master user
Users 2 to 21: System users
User 22: Duress user
500 history events, stamped with time and date
One per user (User 22 does not receive a token or key fob)
Trouble condition occurs when the phone line voltage is between 1.10 V
and 4.75 V
System Reference Guide