116 en | Agency Approvals and Requirements
Paragraph Number
Feature
in ANSI/SIA CP-01
4.3.3
Fire Alarm
Verification
4.5
Call Waiting Cancel Required option
1
Programming at installation site might be subordinate to other UL requirements for the intended application.
2
Combined Entry Delay and Abort Window should not exceed 1 minute.
3
If the cross zone timer ends and a second cross zone point is not faulted, the system sends an intrusion alarm unverified report.
12.5

Underwriters Laboratories (UL)

Household Fire Warning System
Household Burglar Alarm Unit
F01U087835 | 02 | 2008.10
Requirement
Required option
Install at least one UL Listed four-wire latching type smoke detector rated to operate over
the voltage range of 11.2 VDC to 12.3 VDC. The maximum smoke detector load is 50 mA.
Install one UL Listed 85 dB audible device rated to operate over the range of 11.2 VDC to
12.3 VDC as required for this application. Program the bell cut-off time for at least four
minutes. Refer to Programming Item 107 in Section 5.2.2 System Programming Items,
page 43.
Install end-of-line resistor P/N: 47819 after last smoke detector.
Do not use a printer interface module.
Where two-wire addressable devices are used, do not place fire and intrusion devices on
the same zone.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 4 min without AC power.
Install at least one UL Listed 85 dB audible device rated to operate over the voltage range
of 11.2 VDC to 12.3 VDC.
Install at least one IUI-EZ1 Control Center.
Program all zones to use end-of-line supervision.
Install intrusion initiating devices rated to operate over the voltage range of 11.2 VDC to
12.3 VDC.
Program all intrusion zones for audible notification.
Do not exceed 60 sec when programming Exit Delay. Refer to Programming Item 126 in
Section 5.2.2 System Programming Items, page 43. Do not exceed 45 sec when
programming Entry Delay. Refer to Programming Item 127 in Section 5.2.2 System
Programming Items, page 43. Program the bell cut-off time for at least of four minutes.
Refer to Programming Item 108 in Section 5.2.2 System Programming Items, page 43.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 4 min without AC power.
System Reference Guide
Range
Shipping
Default
Depends on control
Disabled
panel and sensors
Depends on user
Disabled
phone line
Easy Series
Recommended
1
Programming
Enabled unless
sensors can self-
verify
Enabled if user
has call waiting
Bosch Security Systems, Inc.