Output Programming Items - Bosch ICP-EZM2 Easy Series System Reference Manual

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

54
en | Programming
5.2.7

Output Programming Items

Programming Item
Fire Output Cadence
Output 1 Function (wired)
Output 2 Function (wired)
Output 3 Function (wired)
Output 4 Function (wired)
Output 5 Function (wireless)
Output 6 Function (wireless)
Output 7 Function (wireless)
Output 8 Function (wireless)
Output 4 Supervised Speaker Driver
(wired)
Default = Country-specific default. Select this programming item to hear the updated default value, or refer to Section 11.3 Country
Code Specific Default Programming Codes
NOTICE!
i
When programming a wireless output (for example, a siren or relay module), do not select an
output function that requires the output to activate for an extended period (for example
System Ready).
F01U087835 | 02 | 2008.10
Item
Selections
Number
600
0 = Temporal Code 3 cadence
1 = Pulse cadence
(two-sec on, two-sec off)
611
0 = Disabled
1 = Intrusion
2 = Intrusion Latching
3 = Fire
4 = Fire Latching
5 = Intrusion and Fire
6 = Intrusion and Fire Latching
7 = System Reset
8 = System On
9 = System Ready
10 = Key Fob On/Off
11 = Key Fob 2-sec Pulse
13 = User Controlled
14 = Interior Intrusion and Fire
15 = System On (Unoccupied)
16 = Intrusion and Fire 2
621
631
641
651
661
671
681
642
0 = Supervised 8 Ω speaker driver
1 = Unsupervised open collector
, page 108
.
System Reference Guide
Easy Series
Manuf.
Default
0
5
5
5
7
5
0
0
0
0
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents