Easy Series
Commercial Burglary, Local
Commercial Burglary, Police Station Connected Protected Premises*
* Systems are approved for Encrypted Line Security when used in conjunction with the C900V2 Conettix IP
Dialer Capture Module and communicating over a packet-switched data network (PSDN).
Commercial Burglary, Proprietary*
* Systems are approved for Encrypted Line Security when used in conjunction with the C900V2 Conettix IP
Dialer Capture Module and communicating over a packet-switched data network (PSDN).
Bosch Security Systems, Inc.
Use the D8108A Attack Resistant Enclosure with the D2402 Mounting Skirt.
Install at least one UL Listed 85 dB audible device rated to operate over the voltage range
of 11.2 VDC to 12.3 VDC. All wiring connections between the control panel and device
must be in conduit.
Do not exceed 60 sec when programming Exit Delay. Refer to Programming Item 126 in
Section 5.2.2 System Programming Items, page 43. Do not exceed 60 sec when
programming Entry Delay. Refer to Programming Item 127 in Section 5.2.2 System
Programming Items, page 43.
Install a tamper switch to protect the enclosure door.
Set Programming Item 116 to 1 (Daily) to ensure the automatic test report is sent on a
daily basis. Refer to Section 5.2.2 System Programming Items, page 43.
Ensure that the integrated communicator is enabled (Programming Item 304 = 0; refer to
Section Global Report Routing Items, page 52). Ensure that the system can send low
battery reports (Programming Item 358 = 1, 2, or 3; refer to Section System Report and
Restoral Routing, page 51).
Install at least one IUI-EZ1 Control Center.
Program the bell cut-off time for at least 15 minutes. Refer to Programming Item 108 in
Section 5.2.2 System Programming Items, page 43.
This system was not evaluated for Bank Safe and Vault applications.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 15 min without AC power.
Refer to Section Commercial Burglary, Local, page 117 for installation requirements.
Ensure that the integrated communicator is enabled (Programming Item 304 = 0; refer to
Section Global Report Routing Items, page 52).
The integrated communicator is enabled (Programming Item 304 = 0; refer to
Section Global Report Routing Items, page 52).
The system has one owner.
The system must be able to operate without AC power for at least 24 hours. The central
station receiver must be able to receive reports without AC power for at least 24 hours.
System Reference Guide
Agency Approvals and Requirements | en 117
F01U087835 | 02 | 2008.10