INSYS Modem 56k Small INT 2.0
You can now configure the INSYS Modem 56k Small INT 2.0 remotely.
Some AT commands are not available in remote maintenance mode. The
AT commands are ATA, ATD, ATO, AT&F, AT/B.
Complete the remote configuration by entering AT*E.
4.
The INSYS Modem 56k Small INT 2.0 is now in the normal data connection
mode. You can now exchange data between your local modem and the IN-
SYS Modem 56k Small INT 2.0, or terminate the connection.
Enter **** to re-initiate a remote configuration.
12.13
Access Control and Security Callback
To protect yourself from unauthorized access via the phone line, the modem may be pro-
tected by a password. This password is used to establish a data connection, for security
callback and remote configuration. This means: If the access control is activated, the sys-
tem will prompt you for a password before outgoing connections and when dialing into
the INSYS Modem 56k Small INT 2.0 for remote configuration. After successful authenti-
cation, the function Security Callback will trigger a callback from the INSYS Modem 56k
Small INT 2.0 to a predefined number.
The factory default standard password is "QWERTY".
Configuration with HSComm
Under "Access Control" (Page 27, Figure 5: HSComm Modem - Tab Modem, Po-
sition 24), you can determine, if you want to use access control with a pass-
word, or if you want to perform a security callback. The password can also be
defined.
Enter the phone number, which the INSYS Modem 56k Small INT 2.0 calls as
response to an incoming call. To call only the caller identified by CLIP, just en-
ter the letter "C" instead of a phone number.
Functions
41