Sharp AR-M455N Service Manual page 228

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

MAIN SUB
U2
11
Content
Counter check sum error (ICU)
Detail
Counter data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly
remedy
inserted.
Save the counter/adjustment values
with the DIAG simulation.
Use DIAG (SIM16) to cancel U2
trouble.
Replace the ICU PWB.
12
Content
Adjustment value check sum error
(ICU)
Detail
Adjustment data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly
remedy
inserted.
Save the counter/adjustment values
with the simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
22
Content
SRAM memory check sum error (ICU)
Detail
MFPC section SRAM memory check
sum error
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and
Initialize the communication
remedy
management table registered in the
SRAM and the FAX soft switch.
Since the registered data are deleted,
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
23
Content
SRAM memory individual data check
sum error (ICU)
Detail
Check sum error for every data in the
SRAM memory of the MFPC section
(Communication management table,
sender registration data, etc.)
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and
Automatically initialize the data related
remedy
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted,
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
Details
AR-M355N/M455N TROUBLE CODES 11 - 11
MAIN SUB
U2
50
Content
HD section individual data check sum
error (ICU)
Detail
Check sum error for every individual
data in HD of the MFPC section (One-
touch, Group, Program, etc.)
Cause
HDD write/read error
Control circuit runaway due to noises
ICU PWB HD access circuit trouble
Check and
Automatically initialize the data related
remedy
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted,
register the data again.
Use SIM 16 to cancel the U2 trouble.
Replace the HD PWB.
Replace the ICU PWB.
80
Content
EEPROM read/write error (Scanner)
Details
Scanner EEPROM write error
Cause
EEPROM abnormality
Scanner PWB EEPROM access circuit
abnormality
Check &
Check that EEPROM is set properly.
Remedy
Record counter/adjustment values with
the simulation to protect the data from
being deleted.
Cancel U2 trouble with SIM 16.
Replace scanner PWB.
81
Content
Memory check sum error (Scanner)
Details
Scanner memory check sum error
Cause
EEPROM trouble
EEPROM which is not initialized is
installed.
Control circuit freeze by noises
Scanner PWB EEPROM access circuit
trouble
Check &
Check that EEPROM is set properly.
Remedy
Record counter/adjustment values with
the simulation to protect the data from
being deleted.
Cancel U2 trouble with SIM 16.
Replace scanner PWB.
90
Content
EEPROM read/write error (PCU)
Detail
PCU EEPROM write error
Cause
EEPROM trouble
PCU PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly
remedy
inserted.
Record counter/adjustment values with
the simulation to protect the data from
being deleted.
Use SIM16 to cancel U2 trouble.
Replace the Controller PWB.
91
Content
Memory check sum error (PCU)
Detail
PCU memory check sum error
Cause
EEPROM trouble
EEPROM which is not initialized is
installed.
EEPROM is not initialized.
PCU PWB EEPROM access circuit
trouble
Hang of control circuit due to noises
Check and
Check that EEPROM is properly
remedy
inserted.
Save the counter/adjustment values
with the simulation.
Use SIM16 to cancel U2 trouble.
Replace the Controller PWB.
Details

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m355n

Table of Contents