MAIN SUB
L4
01
Content
Main motor lock detection
Detail
The motor lock signal is detected for
1.5sec during rotation of the main
motor.
Cause
main motor trouble
Check connection of harness between
the PCU PWB and the main motor.
Control circuit trouble
Check and
Use SIM25-1 to check the main motor
remedy
operation.
Check harness and connector between
the PCU PWB and the main motor.
02
Content
Drum motor lock detection
Detail
The motor lock signal is detected for
1.5sec during rotation of the drum
motor.
Cause
Drum motor trouble
Improper connection of harness
between the PCU PWB and the drum
motor.
Control circuit trouble
Check and
Use SIM6-1 to check the drum motor
remedy
operation.
Check harness and connector between
the PCU PWB and the drum motor.
30
Content
Controller fan motor lock detection
Detail
The motor lock signal is detected
during rotation of the controller fan
motor.
The motor lock signal is detected
during rotation of the HDD fan motor.
Cause
Fan motor trouble
Improper connection of the harness
between the controller PWB and the
fan motor.
Control circuit trouble
Check and
Use SIM 6-2 to check the fan motor
remedy
operation.
Check the harness and the connector
between the controller PWB and the
fan motor.
L6
10
Content
Polygon motor lock detection
Detail
It is judged that the polygon motor lock
signal is not outputted.
Lock signal is checked in the interval of
10sec after starting the polygon motor,
and it is judged that the polygon motor
does not rotate normally.
Cause
The LSU connector or harness in the
LSU is disconnected or broken.
Polygon motor trouble
Check and
Use SIM61-1 to check the polygon
remedy
motor operation.
Check connector and harness
connection.
Replace LSU.
Details
AR-M355N/M455N TROUBLE CODES 11 - 10
MAIN SUB
L8
01
Content
No fullwave signal
Detail
Full wave signal is not detected.
Cause
The PCU PWB connector or the power
unit harness is disconnected or broken.
PCU PWB trouble
12V power source trouble
Check and
Check connection of the harness and
remedy
connector.
Replace PCU PWB.
Replace the power unit.
Replace the controller connection
mother board.
02
Content
Full wave signal width abnormality
Detail
It is judged as full wave signal
frequency abnormality.
(When the detection cycle is judged as
69Hz or above or 42.5Hz or below)
Cause
The connector or harness of the PCU
PWB and the power PWB is
disconnected.
PCU PWB trouble
Power unit trouble
Check and
Check connection of the harness and
remedy
connector.
Replace the PCU PWB.
Replace the power unit.
U1
01
Content
FAX battery abnormality
Detail
FAX backup SRAM battery voltage fall
Cause
Battery life
Battery circuit abnormality
Check and
Check that the battery voltage is about
remedy
2.5V or above.
Check the battery circuit.
02
Content
RTC read abnormality
(common with FAX, on ICU PWB)
Details
The value read from RTC on ICU PWB
is [EE]h (abnormal).
Cause
RTC circuit abnormality
Battery voltage fall
Battery circuit abnormality
Check &
Set the time again with key operation,
Remedy
and check that time advances properly.
Check RTC circuit.
Check that battery voltage is about
2.5V or above.
Check battery circuit.
U2
00
Content
EEPROM read/write error (ICU)
Detail
EEPROM write error
Cause
EEPROM trouble
EEPROM is not initialized.
ICU PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly
remedy
inserted.
Save the counter/adjustment values
with the simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
Details