Sharp AR-M455N Service Manual page 189

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
50
3.TRAY2
5.BPT
50
6.ADU
7.SPF(HIGH)
60
8.SPF(LOW)
Select other than 0 - 1, and
press [START] key.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1.TRAY1
Select 1,
Press [START] key.
and press
[START] key.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
Select 0, and
press [START] key.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
(ABOVE+10: DUPLEX MODE)
53
53-6
Purpose
Adjustment
Function
Used to adjust the DSPF width detection level.
(Purpose)
Section
Item
Operation
Operation/Procedure
1) Set the SPF paper feed guide to the max. position.
2) Select "MAX. POSITION" with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CSUTOM SETTING] key.
5) Set the SPF paper feed guide to A4R size position.
6) Select POSITION 1 with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CSUTOM SETTING] key.
9) Set the SPF paper feed guide to A5R size position.
10) Select POSITION 2 with 10-key.
11) Press [START] key.
The A5R width detection level is recognized.
12) Press [CSUTOM SETTING] key.
13) Set the SPF paper feed guide to the min. position.
14) Select "MIN. POSITION" with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, ERROR is
displayed. When completed normally, COMPLETE is displayed.
50
4.DESK
50
1
50
75
Press [CUSTOM SETTINGS] key.
50
Press [CUSTOM SETTINGS] key,
or terminate copying.
Press [START] key, or
press [CUSTOM SETTINGS] key.
1
AR-M355N/M455N SIMULATION 9 - 63
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
Select 1, and
press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or "ERROR")
Select 2, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
Select 3, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
Select 4, and press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or "ERROR")
53-7
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
Used to enter the SPF width detection adjustment
(Purpose)
value.
Section
DSPF
Item
Operation
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
Item
1 MAX. POSITION Max. width
2 POSITION 1
Adjustment position 1
3 POSITION 2
Adjustment position 2
4 MIN. POSITION Min. width
2) Press [START] key.
3) Enter the set value with 10key.
4) Press [START] key.
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION:
66
2.POSITION 1
:
456
3.POSITION 2
:
713
4.MIN.POSITION:
791
Press [START] key.
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1.MAX.POSITION
1
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Set range Default
0 - 1023
66
456
713
791
1
Press [CUSTOM SETTINGS] key.
66