Sharp AR-M455N Service Manual page 158

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

40-2
Purpose
Adjustment
Function
Used to adjust the manual paper feed tray paper
(Purpose)
width detector detection level.
Section
Paper feed
Item
Operation
Operation/Procedure
1) Open the manual paper feed guide to the max. width.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CUSTOM SETTINGS] key.
5) Set the manual paper feed guide to A4R size width.
6) Select POSITION with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CUSTOM SETTINGS] key.
9) Set the manual paper feed guide to A5/A5R size width.
10) Select POSITION2 with 10-key.
11) Press [START] key.
The A5R width detection level is recognized.
12) Press [CUSTOM SETTINGS] key.
13) Open the manual paper feed guide to the min. width.
14) Select MIN POSITION with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
Select 1 and press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Select 2 and press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 1 ··· COMPLETE (or "ERROR")
Select 3 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 2 ··· COMPLETE (or "ERROR")
Select 4 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
1
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
AR-M355N/M455N SIMULATION 9 - 32
40-7
Purpose
Adjustment/Setup
Function
Used to enter the manual paper feed tray paper
(Purpose)
width adjustment value.
Section
Paper feed
Item
Operation
Operation/Procedure
1) Select the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
1
MAX. POSITION
Max. width
2
POSITION 1
Adjustment point 1
3
POSITION 2
Adjustment point 2
4
MIN. POSITION
Min. value
SIMULATION 40-7
BYPASS TRAY VALUE SETTING. SELECT 1-4, AND PRESS START.
1. MAX. POSITION :
66
2. POSITION 1
:
447
3. POSITION 2
:
704
4. MIN. POSITION :
916
Press [START] key.
SIMULATION 40-7
BYPASS TRAY VALUE SETTING. INPUT VALUE 0-1023, AND PRESS
START.
1. MAX. POSITION
40-11
Purpose
Operation test/Check
Function
Used to check the multi-purpose tray width detec-
(Purpose)
tion adjustment value.
Section
Paper feed
Item
Operation
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
The paper width detection level is also displayed.
MCSS1
Tray 3 size detection 1
MCSS2
Tray 3 size detection 2
MCSS3
Tray 3 detection size 3
MCSS4
Tray 3 size detection 4
Multi Purpose
(MPT width direction detection size is
Tray
displayed.) A4/A3, 11X, B5/B4, 8.5X, A4R,
B5R, A5R, 5.5X, 7.25X, EXTRA
SIMULATION 40-11
TRAY3 SENSOR CHECK..
MCSS1
MCSS2
MCSS3
(Multi Purpose Tray width size: A4/A3)
1
Press [CUSTOM SETTINGS] key.
66
MCSS4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m355n

Table of Contents