Sharp AR-M455N Service Manual page 204

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)
START.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Press [START] key.
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)
START.
EXECUTING···.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Same display
Select 3 and press [START] key.
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)
START.
EXECUTING···.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Press [CUSTOM SETTINGS] key.
66-12
Purpose
Operation test/Check
Function
Used to check the output operation of FAX G3
(Purpose)
mode 300bps. (Used to check the operation of
MODEM.) An output is send at the send level set
by the soft switch. (Only when FAX is installed)
Section
FAX
Item
Operation
Operation/Procedure
1) Select the number corresponding to the output mode with 10-
key.
2) Press [START] key.
The signal is sent in the send level set with the soft switch.
1
NO SIGNAL
No signal
2
11111
11111
3
11110
11110
When the number is entered during execution, the kind of signal
can be changed.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
SELECT 1-6, AND PRESS
4. 00000
1
Press [CUSTOM SETTINGS] key
SELECT 1-6, AND PRESS
1
4. 00000
SELECT 1-6, AND PRESS
3
4. 00000
4
00000
00000
5
010101
010101
6
00001
00001
AR-M355N/M455N SIMULATION 9 - 78
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)
START.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Press [START] key.
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)
START.
EXECUTING···.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Same display
Select 3 and press [START] key.
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)
START.
EXECUTING···.
1. NO SIGNAL
2. 11111
3. 11110
5. 010101
6. 00001
Press [CUSTOM SETTINGS] key.
66-13
Purpose
Setting
Function
Used to enter (set) the number of FAX dial signal
(Purpose)
output test. (The dial number set by this simulation
is outputted when the dial signal output test is
made by SIM 66-14 - 16. ) (Only when FAX is
installed)
Section
FAX
Item
Data
Operation/Procedure
1) Enter the dial number with 10-key.
Use 10-key, [*] key, and [#] key to enter the number. The
upper limit is 20 digits.
When [CLEAR] key is pressed, the mode returns to the initial
state.
2) Press [START] key.
SIMULATION 66-13
DIAL TEST NUMBER SETTING.
INPUT NUMBER AND PRESS START.
0123456789*#01234567
66-14
Purpose
Setting/Operation test/Check
Function
Used to set the make time in the FAX pulse dial
(Purpose)
mode (10pps) and to test the dial signal output.
(The dial number signal set by SIM 66-13 is
outputted.) Used to check troubles in dialing and
to check the operation. (Only when FAX is
installed)
Section
FAX
Item
Operation
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key.
The dial signal is outputted.
SELECT 1-6, AND PRESS
1
4. 00000
Press [CUSTOM SETTING] key.
SELECT 1-6, AND PRESS
1
4. 00000
SELECT 1-6, AND PRESS
2
4. 00000
0-9:[0-9], *:[*], #:[#]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m355n

Table of Contents