5. Automatic developer adjustment

1) Attach the cabinets which were removed.
2) Close the left door.
At that time, keep the front door open.
Note: The automatic developer adjustment must be performed by
entering the simulation mode with the front door open. If the
power is turned on with the front door closed, warm-up is
performed to supply toner to the developing unit. As a
result, the reference toner density cannot be obtained.
3) Insert the power plug into the power outlet.
4) Go through the modes specified in Simulation 25-2.
5) Close the front door.
(LCD Display)
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
HUMIDITY AREA:
70.0
TEMPERATURE AREA:
70.0
DEVE REFERENCE:
128
Press [START] key.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after 2 min.
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTING···.
HUMIDITY AREA:
70.0
TEMPERATURE AREA:
70.0
DEVE REFERENCE:
118
6) Press the [START] key, and the automatic developer adjust-
ment will be performed.
During execution of the automatic developer adjustment,
"EXECUTING..." is displayed and the toner sensor value is
indicated on the LCD. (DEVE REFERENCE)
7) After about 2 min, the adjustment value is stored in the
machine. Check that the mode was normally completed.
Normal end:
Returns to the initial window (PRESS
START display).
Abnormal end: Returns to the initial window (PRESS
START display), and indicates the trouble
display (TROUBLE! EE-**).
In case of an error end, remove the cause of the error, and
execute the automatic developer adjustment again.
8) Turn off/on the power, and the machine returns to the normal
mode and enters the warm-up mode.

6. Print test

1) After completion of warm-up (normal mode), select [CUSTOM
SETTINGS]
[Data list up] to display the menu.
2) Print [ALL SETUP LIST] to check and confirm the print quality.
3) Press the [CUSTOM SETTINGS] key again to return to the
normal menu.
-
72.5
-
72.5
-
72.5
-
72.5
AR-M355N/M455N UNPACKING AND INSTALLATION 6 - 5

7. Attach the document scanning label

Reference
6mm
Reference
15mm

8. Adjuster installation and adjustment

1) Insert the left adjuster into the paper feed desk.
2) Turn each adjuster until it is brought into contact with the floor.
2
2
1
Be sure to install the left adjuster in order to prevent falling down
of the machine.
Note: If the adjusters are not lowered to the specified positions,
the lower stage tray cannot be pulled out.
9. Using the transport handle
1) Remove the screw, and remove the handle.
2