D. In case of "Result: NG"

(1) Possible causes of "Result: NG"
There are following possible causes of "Result: NG."
1) The DIP switch of write protect is not set properly.
• The write protect switch of the controller PWB is not set to
the release side (lower side).
→ If the write protect switch is not set to the release side,
data are not written into the ROM. Set the DIP switch
properly, and retry updating.
2) The FAX cable is not connected. The FAX is NG.
→ Writing is not made. Connect properly and retry writing.
3) In rare cases, the ROM is broken down.
→ Check the ROM, and retry writing. If the trouble remains,
replace the ROM.
(* There are three types of ROM device: the common type for
the PCU and the scanner, the common type for BOOT and
MAIN, and the exclusive type for FAX.)
E. Turning off the power during update
When the power is turned off during the update process, though
the machine is booted, data writing cannot be assured. Retry
update as follows.
1) When the power is turned off during update process of (B.)
Retry the update procedure of (B.). If the machine is not
booted or the hard keys are not invalid (**), or retry of the
update is failed again, replace the ROM's with the spare one
of the PCU, the controller BOOT, and the scanner ROM, and
try the update procedure of (C.) for the replaced ROM's.
(** When the backlight of the display is lighted but the hard
keys are invalid, all LED's flash.)
2) When the power is turned off during update process of (C.)
Retry updating.
F. Update window display in normal booting
After completion of updating, when the power is turned off and the
DIP switches on the back of the machine are set to the normal
side and the machine is booted, the update window is displayed
as shown below instead of the normal boot window, the PCU or
the scanner may not have been properly updated.
Version Check
CONF: *********
At that time, use Up/Down key to check the version of the PCU or
the scanner. If the version is displayed as "BootMode," or if the
key operation is invalid (all the LED's are flashing), retry updating
as follows.
1) When the key operation is possible and the version is dis-
played as "BootMode"
Turn off the power and retry the update procedure of (B.). At
that time, be sure to set the DIP switches properly. After
updating again, if the result is still NG, replace the ROM's with
the spare one of the PCU and the scanner ROM, and perform
the update procedure of (C.) for the replaced ROM's.
2) When the key operation is invalid
Turn off the power and replace the ROM's with the spare one
of the PCU and the scanner ROM, and perform the update
procedure of (C.) for the replaced ROM's. Be sure to set the
DIP switches properly.
AR-M355N/M455N ROM VERSION-UP METHOD 12 - 3
G. Update process flow
The brief descriptions on the update procedures are as follows.
For turning off during update, refer to "E. Turning off the power
during update."
If the update window is displayed after booting with the DIP
switches on the back of the machine set to the normal side, refer
to "F. Update window display in normal booting."
Write with the onboard
collective files.(B)
Reset
Result: OK ?
NO
YES
Setting failure ?
NO
YES
Boot NG?
NO
YES
SCN, FAX NG?
NO
YES
Update completed
(D.)