(Scan off-center position adjustment)
1) Enter the scan image position adjustment value with 10-key.
2) Press [P] key or [START] key.
When [START] key is pressed, the adjustment value is set and
copying is performed.
Normal display
ERROR display
Door open
Jam
Paper empty
Check the off-center of the printed image.
Repeat the above procedures until a satisfactory result is
obtained.
(UNIT: 0.1mm/step When the adjustment value is increased, the
print image is shifted to the front direction.)
(Copy condition setting in this simulation)
∗ To select paper (paper feed tray), perform the following proce-
dures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed
tray selection mode.)
3) Enter the number corresponding to the paper feed tray to be
used with 10-key. (Select one of 1 - 6)
4) Press [START] key. (The paper feed tray is selected.)
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
BPT
When the total of the above set value (1 - 5) and 10 is entered, the
mode is changed to the duplex print mode.
∗ To set the copy magnification ratio, perform the following proce-
dure.
1) Enter 2 with 10-key.
2) Press [START] key.
3) Enter the copy magnification ratio with 10-key.
4) Press [START] key.
Set range
25 - 400 (%)
NOTE: When [P] key is pressed after entering the adjustment
value in this simulation, the adjustment value is set. When
[START] key is pressed, the adjustment value is set and
copying is performed.
NOW COPYING.
DOOR OPEN.
JAM
PAPER EMPTY.
TRAY1
TRAY2
TRAY3
TRAY4
Manual feed
AR-M355N/M455N SIMULATION 9 - 61
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 0-9, AND PRESS
START.
0.TRAY SELECT
1
1.COPY START
2.MAGNIFICATION
100
(ADJUSTMENT DATA)
3.PLATEN
50
4.SPF SIDE1
Select other than 0 - 2, and press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. INPUT VALUE 0-99, AND
PRESS START.
3.PLATEN
Select 1,
Press [START] key.
and press
[START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. NOW COPYING.
Select 0, and press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 1-15, AND PRESS
START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
(ABOVE+10: DUPLEX MODE)
Select 2, and
press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
50-27
Purpose
Adjustment
Function
Used to adjust the image loss of the scan image in
(Purpose)
the FAX/scan mode.
Item
Picture quality
Operation/Procedure
(Select the scan mode to be adjusted.)
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(Shift for the adjustment value change: 1.0mm/step)
Item
FAX send
1
OC (LEAD_EDGE)
OC lead edge
2
OC (FRONT/REAR)
OC side
3
OC (TRAIL_EDGE)
OC rear edge
4
SPF (LEAD_EDGE)
SPF lead edge
5
SPF (FRONT/REAR) SPF side
6
SPF (TRAIL_EDGE) SPF rear edge
7
CIS (LEAD_EDGE)
CIS lead edge
8
CIS (FRONT/REAR) CIS side
9
CIS (TRAIL_EDGE)
CIS rear edge
2
50
5.SPF SIDE2
50
Press [CUSTOM SETTINGS] key.
50
Press [CUSTOM SETTINGS] key,
or terminate copying.
Press [START] key or
press [CUSTOM SETTINGS] key.
1
Press [START] key, or
press [CUSTOM SETTINGS] key.
100
Set range
Default
0 - 10
3
(Unit 1mm)
(3mm)