Sharp AR-M455N Service Manual page 226

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

MAIN SUB
F7
01
Content
FAX board EEPROM read/write error
Details
EEPROM access error (read/write)
Cause
EEPROM trouble
FAX PWB EEPROM access circuit
trouble
Check &
When replacing the EEPROM, use
Remedy
SIM66-4/5 (Signal send level) and
SIM66-14/15/16 (Dial test) for
adjustment. However, note that all the
soft switches are reset to the initial
values.
No need to adjust when the PWB is
replaced.
H2
00···
Content
Thermistor open
HL1
Fusing unit not installed
Detail
Thermistor is open.
01···
(An input voltage of 2.92V or above is
HL2
detected.)
Fusing unit not installed
Cause
Thermistor trouble
Control PWB trouble
Fusing section connector
disconnection
AC power trouble
Fusing unit not installed
Check and
Check harnesses and connectors from
remedy
the thermistor to the control PWB.
Use SIM14 to clear the self diag
display.
H3
00···
Content
Fusing section high temperature
HL1
trouble
Detail
The fusing temperature exceeds
01···
242°C. (An input voltage of 0.27V or
HL2
above is detected.)
Fusing temperature control is started,
and 242°C is detected three or more
times continuously in sampling in the
specified interval. (Every 300msec)
Cause
Thermistor trouble
Control PWB trouble
Fusing section connector
disconnection
AC power trouble
Check and
Use SIM5-2 to check the heater lamp
remedy
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its
harness.
Check the thermistor input circuit in
the control PWB.
If the heater lamp keep lighting:
Check the AC PWB and the lamp
control circuit in the control PWB.
Use SIM14 to cancel the trouble
Details
AR-M355N/M455N TROUBLE CODES 11 - 9
MAIN SUB
H4
00···
Content
Fusing section low temperature trouble
HL1
Detail
The set temperature is not reached
within the specified time (3 min) after
01···
turning on the power relay, or the
HL2
temperature does not reach 80°C
within 80 sec.
When the heater lamp is not turned off
in the specified time (3 min) from
starting warm-up, or the temperature
does not reach 80°C within 80 sec.
After completion of warm-up operation,
a temperature 50°C lower than the
temperature control level is detected 5
times continuously in sampling in the
specified interval. (every 300msec)
Cause
Thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch trouble
Check and
Use SIM5-2 to check the heater lamp
remedy
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its
harness.
Check the thermistor input circuit in
the control PWB.
If the heater lamp does not light:
Check for heater lamp disconnection
and thermostat disconnection.
Check the interlock switch.
Check the AC PWB and the lamp
control circuit in the control PWB.
Use SIM14 to cancel the trouble.
H5
01
Content
5-time continuous POD1 not-reaching
jam detection
Detail
5-time continuous POD1 not-reaching
jam detection
Cause
A fusing section jam is not properly
removed. (Jam paper remains.)
POD1 sensor trouble, or harness
disconnection
Improper installation of fusing unit
Check and
Check jam paper in the fusing section.
remedy
(winding, etc.)
Check POD1 sensor harness, and
check the fusing unit installation.
Use SIM14 to cancel the trouble.
L1
00
Content
Scanner feed trouble
Details
Scanner feed is not completed within
the specified time.
Cause
Scanner unit abnormality
Scanner wire disconnection
Check &
Check scanning with SIM 1-1.
Remedy
L3
00
Content
Scanner return trouble
Details
Scanner return is not completed within
the specified time.
Cause
Scanner unit abnormality
Scanner wire disconnection
Check &
Check scanning with SIM 1-1.
Remedy
Details