Sharp AR-M455N Service Manual page 142

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

SIMULATION 8-17
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT
160
2.SHV BACK
160
3.THV-
780
Press [START] key.
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-240)
Press [START] key.
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-240)
9
9-1
Purpose
Operation test/Check
Function
Used to check and adjust the operation of the load
(Purpose)
(clutch/solenoid) in the duplex section and the
control circuit.
Section
Duplex
Item
Operation
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [CUSTOM SETTINGS] key to stop the operation.
1
ADMEN1
ADU motor 1 control signal
2
ADMEN2
ADU motor 2 control signal
3
DGS
ADU gate solenoid
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1.ADMEN1
2.ADMEN2
3.DGS
Press [START] key.
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1.ADMEN1
2.ADMEN2
3.DGS
1
Press [CUSTOM SETTINGS] key.
160
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
160
1
Press [CUSTOM SETTINGS] key to
stop the operations.
1
AR-M355N/M455N SIMULATION 9 - 16
9-2
Purpose
Operation test/Check
Function
Used to check the operations of the sensors and
(Purpose)
detectors in the duplex section and its control
circuit.
Section
Duplex
Item
Operation
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The active sensors and detectors are highlighted.
ADUSET
ADU installation detection
DSW_D
ADU cabinet open detection
AINPD
ADU paper entry detection
APOD
ADU paper exit detection
APPD1
ADU paper detection 1
APPD2
ADU paper detection 2
SIMULATION 9-2
ADU SENSOR CHECK.
ADUSET
DSW_D
AINPD
10
10-1
Purpose
Operation test/Check
Function
Used to check the operations of the toner motor
(Purpose)
and the related circuit.
Section
Process (Developing)
Item
Operation
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Never execute this simulation with toner in the toner hop-
per.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
1
Toner motor rotation start
2
Cancel (The display returns to the main code entry menu.)
SIMULATION 10-1
TONER MOTOR ACTIVATION.
ARE YOU SURE?
1.YES
2.NO
Press [START] key.
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
APOD
APPD1
APPD2
2
Press [CUSTOM SETTINGS] key to
stop the operations. Or after 10sec.
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m355n

Table of Contents