Sharp AR-M455N Service Manual page 140

Digital multifunctional system
Hide thumbs Also See for AR-M455N:
Table of Contents

Advertisement

7-6
Purpose
Setting
Function
Used to set the intermittent aging cycle.
(Purpose)
Section
Item
Operation
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
∗ Set range of interval time: 1 - 999 (sec)
Set the intermittent aging mode cycle of 7-1 with 10-key. (Unit:
sec)
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
7-8
Purpose
Setting
Function
Used to set the warm-up time display YES/NO.
(Purpose)
Item
Operation
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1)
is set.
∗ The setting of this simulation is kept valid until the power is
turned off.
The warm-up time is displayed in the unit of second.
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
Press [START] key,
and time count is started.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
Warm-up is completed.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
10
1
Press [CUSTOME SETTING] key,
and time count is stopped.
30
Press [CUSTOM SETTINGS] key.
60
AR-M355N/M455N SIMULATION 9 - 14
8
8-1
Purpose
Adjustment/Operation test/Check
Function
Used to check and adjust the operations of the
(Purpose)
developing voltage of each color and the control
circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The developing bias output voltage adjustment and output check
can be made in each print mode.)
Item
1 AUTO
Auto mode
2 CHARACTER Text mode
3 MIX
Text/Photo mode
4 PHOTO
Photo mode
5 PRINTER
Printer mode
6 FAX
FAX mode
7 PLUS
Reverse
developing bias
voltage
SIMULATION 8-1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO
485
2.CHARACTER
3.MIX
485
4.PHOTO
485
5.PRINTER
485
6.FAX
485
Press [START] key.
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-745)
Press [START] key.
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
Default
Set
AR-
AR-
range
M355N
M455N
0 - 745
455
485
485
485
0 - 255
150
150
485
1
7.PLUS
150
Press [CUSTOM SETTINGS] key.
485
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
485