VOID
Sets the distance (0.10 - 2.00 inches) to retract the faulted label to print a
DISTANCE
'VOID' on its trailing edge; this distance indirectly establishes the font size of
the void message.
0.50
Is the Default Setting.
RETRY
Establishes the number of times (0 - 3) a label reprinting attempt will be
COUNT
made. If the last label printed in this count has been voided, the printer will
stop and display a fault message.
1
Is the Default Setting.
Determines the printer's response when a fault is detected and cleared.
BACKFEED
ON CLEAR
ENABLED
After clearing a fault, no backup positioning will occur; the printer will assume
the current label position is correct. (If reloading media, the operator must
place the material in its presented position.)
DISABLED
After clearing a fault, backup positioning will occur. (Default Setting)
Note: Retry counts greater than 1 are only valid for printers equipped
with the Linear Scanner or RFID option.