Code128 and UCC/EAN 128 Options

Setting
Minimum
Label Length
Read
Verification
QuadraLogic
™ II
Decoding
RF Programming Manual
These Code 128 and UCC/EAN 128 features are specific to the
scanner ONLY
The Code 128 and UCC/EAN 128 symbologies have the following pro-
grammable feature.
Minimum Label Length
Read Verification
QuadraLogic™ II Decoding
Setting Minimum Label Length sets the minimum length required for
Code 128 and UCC/EAN symbology. This feature causes the scanner
to ignore small label segments, reducing the possibility that a portion
of a good label is incorrectly seen as an entire label.
Read Verification is the number of times the scanner is required to read
the bar code data before sending the label data to the host.
QuadraLogic™ II Decoding directs the scanner to decode labels with
widespread problems of spots, voids, and/or non-uniform widths.
To optimize your scanner's performance activate this option only for
symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and
decode extremely poor labels. Contact your sales representative or ser-
vice provider for other advanced QuadraLogic™ II Decoding settings.