Configuring
the Code 93
Options
Minimum
Label Length
RF Programming Manual
Code 93 options are specific to scanner ONLY
Use these special bar codes to configure the Code 93 options.
1.
Identify the minimum length setting you want to make. The
selectable range is 01 to 50
2.
Scan the SET bar code.
3.
Scan the SET MINIMUM LABEL LENGTH bar code.
4.
Set the minimum label length by scanning the applicable digits
from page 130. The range is 01 to 50
page and go to step five.
If you are setting a label length less than ten, you
must scan a zero digit first and then the length
digit (e.g., 04, 06, 08).
NOTE
5.
Scan the END bar code.
SET ------------------------------------------
Set Minimum Label Length ---------
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will
vary depending upon interface type, and bar code physical size and quality. The IBM POS inter-
face is limited to 32 character labels. Code 93 bar codes containing one or more shift characters
can also limit the amount of characters that will be decoded (in these circumstances, the scanner
will decode at least 39 data characters).
1
characters.
1
characters. Return to this
129