Connecting To The Ir360 Base - Bosch UPH series Operation Manual

High-speed positioning system (hsps)
Hide thumbs Also See for UPH series:
Table of Contents

Advertisement

High-Speed Positioning System
(HSPS)
7

Connecting to the IR360 Base

The IR360 base has a 16-pin connector for which the following connections are illustrated:
Reference
F1 and F2
O1 and C1
(O=Output, C=Common)
AL1 and AL2
AGND
LNO
Bosch Security Systems, Inc.
Description
Feed 1, 24 VAC for optional washer; Feed 2, 24 VAC for optional
washer
Dry contact output that can be activated by alarm or by user (50
VDC or 30 VAC @ 1A)
Alarm inputs 1-2, voltage-controlled (10-35 VDC supplied
externally), referred to AGND
Alarm Ground & External IR probe common
External photosensor/IR probe
Operation Manual
Connecting to the IR360 Base | en
2013.11 | 5.2 | F.01U.291.981
31

Advertisement

Table of Contents
loading

Table of Contents