60
en | Configuring the System
> 1 - START POSITION
Feature
START POSITION
END POSITION
FIRST PRST SPEED Speed at which the UPH reaches the
RANDOM
Note: *IR models are limited to 40 deg/s on pan
Autopan
The Autopan menu is used to indicate preset position settings.
> 1 - START POSITION
2013.11 | 5.2 | F.01U.291.981
2 - END POSITION
3 - FIRST PRST SPEED
4 - RANDOM
Description
The first preset position considered
valid for carrying out the patrol function.
The last preset position considered valid
for carrying out the patrol function.
first preset position when the patrol
function is activated.
Increase the First PRST Speed from the
default value to reach presets faster.
Enables execution of the Patrol function
by passing through the defined positions
in a random manner. The random
sequence is continually recalculated.
AUTOPAN MENU
2 - END POSITION
3 - REACH SPEED
4 - FORWARD SPEED
5 - REVERSE SPEED
: 00001
: 00250
: 20.0
: N
: 0000
2
: 0000
1
: 10.0
: 10.0
: 20.0
Operation Manual
High-Speed Positioning System
Default
Options
00001
00001 to 00250
00250
00001 to 00250
20.0
01 to 100.0°*
NO
YES, NO
Bosch Security Systems, Inc.