Maintenance

UPH pan/tilt devices require no particular maintenance.
16.1

Cleaning

To clean the device, use neutral detergent and a non-abrasive cloth.
16.2

Replacing the Fuses

Caution!
!
Replacement of fuses must be carried out by skilled personnel.
Caution!
For continued protection against risk of fire, replace, only with same type and rating of fuse.
!
There are two (2) preset fuses on the connection board. Sizes are related to the power supply
voltage, as shown in the table below.
Figure 16.1: Fuses on the Connection Board
Standard Models: Fuse Values for Replacement (Reference #1)
Refer to , page 77, Item 1, above for fuse locations.
Voltage
24 VAC 50/60 Hz
120 VAC 50/60 Hz
230 VAC 50/60 Hz
IR Modes: Fuse Values for Replacement (Reference #2)
Refer to , page 77, Item 2, above for fuse locations.
Voltage
24 VAC 50/60 Hz
Bosch Security Systems, Inc.
Fuse F1
Fuse F2
T 4A L 250 V
T 6.3A H 250 V
T 4A L 250 V
T 4A H 250 V
T 4A L 250 V
T 2A H 250 V
Fuse F1
Fuse F2
T 4A L 250 V
T 8A H 250 V
Operation Manual
Maintenance | en
F2
2013.11 | 5.2 | F.01U.291.981
77