Bosch UPH series Operation Manual page 23

High-speed positioning system (hsps)
Hide thumbs Also See for UPH series:
Table of Contents

Advertisement

High-Speed Positioning System
(HSPS)
4.
5.
2
3
4
5
Figure 5.3: Schematic Diagram
Reference
1
2
3
4
5
6
7
Securing the base to the mount
1.
2.
3.
Bosch Security Systems, Inc.
Securely lock the cable glands into place, using a gland closing torque of 5 N m. Use a
calibrated torque wrench to ensure closure.
Note: The cable glands accept cables 5-10 mm (0.2-0.39 in.) in diameter. They can be
changed to accept smaller 3-7 mm diameter cables by using the two (2) conduit plugs
(supplied).
Position the base on the optional wall or pole mount, guiding the cables so that they are
positioned inside the wall or pole mount (see the figure Schematic Diagram below).
6
1
Description
Base
Gasket
Screw seals
(4)
Washers (4)
Screws (4)
Bracket
Support
Apply thread locker (such as Loctite 243) on the holes of the screws.
Secure the base to the wall or pole mount with the screws and washers (supplied).
Tighten the screws to 4 N m using a calibrated torque wrench.
Installing the High Speed Positioning System | en
2
3
4
5
Operation Manual
23
1
7
2013.11 | 5.2 | F.01U.291.981

Advertisement

Table of Contents
loading

Table of Contents