en | Configuring the System
Feature
ZOOM
FOCUS
IRIS
SPEED
DWELL
TXT: PRESET
Note: *IR models are limited to 40 deg/s on pan
Special Preset Parameters
The Special Preset Parameters menu can be used to make parameter settings. Increase the
default value to increase the speed between presets or the scan speed.
> 1 - PRESET SPEED REF.
Table 12.5: Special Preset Parameters
2013.11 | 5.2 | F.01U.291.981
Description
Changing the effective focal length to
allow different fields of view to fill
the picture area. Zoom can be
optical, where the lens is adjusted,
or digital, where a portion of the
view selected is magnified
electronically.
Positions
Positions
Speed for reaching the position
when the preset position is loaded
by the patrol function (preset tour).
Dwell time during patrol and autopan
movements.
Message displayed when the preset
position is reached.
SPECIAL PRESET PAR MENU
2 - SCAN SPEED
3 - TILT SPEED REDUC.
6 - PRST DWELL TIME
7 - FORCE PRST DW.TIME
8 - FORCE PRST SPEED
: 20.0
: 20.0
: 100
:00005
:N
:N
Operation Manual
High-Speed Positioning System
Default
Options
00000
65535
00000
65535
00000
65535
040.0
.1 to 100.0°*
00001
00000 to 01000
sec.