[Note]
Restriction of printing
by chart speed
When the chart speed is 0 ‡ o /h, it's printed with forcible chart feed. (When the chart speed is more than 120
‡ o /h, not printing as shown the Table above.) List Print, Engineering List Print , Manual Print (key), DI
Comment print (Asynchronous) , DI Date and Time print (Asynchronous) , DI Manual print (Asynchronous)
and Logging print (Asynchronous) is printed regardless of the chart speed.
7.1.5 Setting the Date and Time
Operation
The following describes how to set the date/time of the internal clock.
Setting
• @ • @
Example) When setting the date and time to January 1st, 2000, 6:00.
Display
• @
[Note]
If you enter a non-existent dates or time, displays an error
Press the • g ENT• h key and re-enter a correct numeral.
Alarm occurrence print, Alarm recovery print, Affix print,
DI Comment print (Synchronous), DI Date and Time print
(Synchronous), DI Manual print (Synchronous)
Logging print (Synchronous)
Year
Month, Day
Operation keys
ESC
3sec
MENU
ENT
PRINT
PRINT
FEED
ENT
PRINT
FEED
ENT
PRINT
FEED
ENT
ENT
59• \
Print type
Time
Description
Hold down the • g MENU• h key for 3 seconds or more
to enter the setup mode. Use the • ¢
"," and press the • g ENT• h key.
Set the year. Use the • ¢
and use the key to shift a digit.
Press the • g ENT• h key.
Set the month and day.
Operate in the same manner as setting the year.
Set the time (hours and minutes).
Operate in the same manner as setting the year.
Press the • g ENT• h key. To return to the user mode,
hold down the • g MENU• h key for 3 seconds or more.
Chart speed• i ‡ o /h• j
1• ` 100
10• ` 100
key to display
key to select a numeral,
.
HXPRM10mnCT001E
Need help?