About This
Manual
1
This manual provides information for planning, installing, programming, and testing
this security system. When necessary, this manual refers you to other documentation
included with compatible devices.
Planning sheets are included for you to record sensor locations and software program-
ming settings.

Special Installation Requirements

This security system can be used as a fire warning system, an intrusion alarm system, an
emergency notification system, or any combination of the three.
Some installations may require configurations dictated by city/state codes, insurance, or
Underwriter's Laboratories (UL). This section describes the various component and
configuration listings.

UL Listed Installations

This section describes the requirements for UL Listed installations.
Basic System
Control Panel:
60-875-95R (basic panel)
60-875-01-95R (with *2-way voice)
60-875-10-3 (with *transmitter)
60-875-11-3 (with *2-way voice and *transmitter)
Backup Battery 6V 1.2 AH (34-025)
Standard Class II 9 VAC, 700 mA Power Transformer (22-109) or Class II 9 VAC,
700 mA Line Carrier Power Transformer (22-129)
Hardwire Interior Siren (13-374) or Hardwire Exterior Siren (13-046)
* Not investigated for use by UL.
Household Burglary Alarm System Unit (UL 1023)
Basic system, plus:
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/
Window Sensor (60-670)
Option 01: Panel Piezo Beeps set to on
Option 10: Entry Delay set to 45 seconds or less
Option 11: Exit Delay set to 60 seconds or less
Option 19: RF Timeout set to 24 hours
Option 29: Control Panel Alarms turned on
Option 38: Auto Arm set to on
Option 39: Siren Timeout set to 4 minutes or more
Option 40: Trouble Beeps set to on
Option 50: RF Jam Detect set to on
Option 53: Hardwire Siren Supervision set to on if Option 29: Control Panel
Alarms is set to off
Option 59: Exit Extension set to off
Option 67: Quick Exit set to off
Household Fire Warning System (UL 985)
Basic system, plus:
Wireless Smoke Sensor 60-848-95 learned into sensor group 26
Option 01: Panel Piezo Beeps turned on