The Positive Close Mode feature can be enabled on one or
both leaves of a double swing gate installation in addition to
adjusting the amount of force applied by the operator

3.1.9. Operator Run Profiles

In order to set up the system for optimum performance a number of the
operating parameters can be adjusted via the controller.
The opening and closing speeds of the gate can be independently set
but common between the two leaves of a double swing gate installation.
The ramp-up to full speed and the ramp-down to the crawl speed before
the gate stops can also be adjusted. The distance that the gate moves
at its crawl speed before stopping can also be set.
Please contact CENTURION for more information on finding the
configuration that is best for you.

3.2. Gate Lock

The VECTOR2 controller provides a 12V supply to drive either an
electric solenoid or magnetic lock. Both the lock pre-release time (time
before the gate starts to move) and the release time (time while the
gate is moving) can be adjusted in addition to being able to specify
whether the gate is locked in either the open or closed position or both.
Finally, the supply can be set to either AC or DC where with AC, the
controller will power the lock with a 50Hz square wave.
Contact your gate automation specialist for assistance.
page 15