Anti-Crushing Sensitivity - Centurion Vector2 User Manual

Linear swing gate operators
Hide thumbs Also See for Vector2:
Table of Contents

Advertisement

3.3. Anti-crushing
Sensitivity
The VECTOR2 incorporates, a
sensitive electronic anti-
crushing technology that
Features
activates if a person or vehicle
and
obstructs your gate.
functions
If the anti-crushing circuitry is
invoked during the opening
cycle, then the controller will
stop the gate. The second gate
leaf (if fitted for a double-swing
system) will continue to open.
Once the obstruction is cleared,
the obstructed gate can
immediately be operated using
the remote control, or gate
release pushbutton, or other
access control device (refer to
Multiple Collision overleaf), the
gate will close.
If the gate is closing, both
leaves will re-open, regardless
of whether the anti-crushing
mechanism on one or both
leaves senses the obstruction.
As per the above, when
triggering the system again, the
gate will close.
Collision force can be set
independently per direction of
travel and can be set from
minimum to maximum in five
incremental steps. A sixth
incremental step will disable
collision sensing entirely and
allow for maximum force – the
motor will run until it stalls at
which point a collision will be
detected.
Step six referred to above, should only be used if additional
safety measures such as infrared beams and passive sensitive
edges are present
page 16
Obstructed gate stops,
unobstructed gate opens
Gates closing onto an obstruction
Both gates automatically reopens
FIGURE 16
FIGURE 17
FIGURE 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vector2 400

Table of Contents