Specifications - Centurion Vector2 User Manual

Linear swing gate operators
Hide thumbs Also See for Vector2:
Table of Contents

Advertisement

Specifications

8. Specifications
Technical specifications
Input voltage
Motor voltage
Motor power supply
Battery charger
Domestic
Light-industrial
Current consumption (mains)
Current consumption (motor at
rated load)
Operator push force - maximum
Operator stroke
Piston extension / retraction speed
Typical gate opening time
Manual override
Maximum number of operations per
day
Duty cycle - mains present
Operations in standby with 7Ah
battery
Half day
Full day
Collision sensing
Controller solenoid output rating
Operating temperature range
Onboard receiver type
Receiver code storage capacity
Receiver frequency
Mass of unit packed (excluding
battery)
Single kit
Double kit
Can operate off a solar supply, consult Centurion Systems for assistance
Can increase battery capacity for longer standby times
Based on 25°C ambient temperature and unit not in direct sunlight
Based on an operator push force of less than 50% of rated
Based on double kit excluding infrared safety beams
Assumes a 90° opening gate and optimum mounting position
Assumes full stroke of operator is used
220V AC ± 10%,50Hz
12V DC
Battery driven (standard capacity -
7Ah)
CP84E - 800mA @ 13.8V
CP84SM - 2A @13.8V
60mA
15A - max
250kgf
400mm
27mm/sec
<14 sec
Key release
100
/ 250
25%
70
58
Electronic
2A DC
-15°C to +50°C
CENTURION rolling code (Keeloq
encryption) multichannel
64 transmitter buttons
433MHz
8.5kg
14kg
page 32
VECTOR2 400
/ 170mA
/ 50%
TM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vector2 400

Table of Contents