Page 2
Product Guarantee D3 and D5, version 3 The CENTURION D3 and D5 Version 3 sliding gate operators are manufactured with extreme care, thoroughly inspected and tested. The operators are only guaranteed against faulty materials or workmanship for a period of 24 months from the invoice date of the operator or 26 months from the manufacturing date (as shown on the serial number label of the operator), whichever expires first.
OPERATORS to ensure that YOU, the user, get the most from your system. Basic maintenance is also described, but in the event of product malfunction, you are advised to contact your installer, or your local Centurion branch (refer to back page). Models Covered...
Page 8
Accordingly the unit is resistant to forced entry. The integral electronic controller has similar functions to those of the D3/D5 and uses the same technology in terms of origin & encoder signal inputs. Unique to the A10 is the high speed mode, enabling adjustable opening/closing speeds up to 30m/min.
The gate will close automatically after the auto-close delay time. INTERCOM PUSH BUTTON: Most automatic gate installations are fitted with an intercom which provides for communication between the house and the gate. The intercom handset is usually Centurion Sliding Gate Operators User Guide - 9...
The gate can be held open by keeping the key turned in the keyswitch. As soon as the key is released back to its normal rest position, the gate will close after the 5 second 10 - Centurion Sliding Gate Operators User Guide...
It is also required if the mains power has failed in the case of the 220V operators ( A10 and FAAC models). In the case of the CENTURION operators (D3, D5, A10) when a command signal is given after the gate has been moved manually and then re-engaged, the gate will drive to either it’s fully open, or closed, position.
EVERY 2 SECONDS TO INDICATE BATTERY VOLTAGE IS LOW. fitted inside the house, there is an equivalent LED - D3/D5 OPERATOR PCB SHOWN. mounted on the controller marked “STATUS”. RED LED STATUS Centurion Sliding Gate Operators User Guide - 13...
SENSOR is checked by a qualified technician. LIGHTNING PROTECTION All CENTURION controllers have on board lightning protection. The protection circuitry was designed in conjunction with the CSIR. Provided that the system has been properly earthed the protection will significantly improve the resistance of the system against lightning strikes.
This warns the pedestrian that the gate will open within 5 seconds allowing time to remove the key and stand back from the gate. PRE-FLASHING The courtesy light can be programmed to flash for a period of time before the gate Centurion Sliding Gate Operators User Guide - 15...
It is necessary to have at least a 35A/H deep cycle low maintenance battery fitted, in order to provide sufficient backup capacity during days of poor weather. For further details contact your local CENTURION agent. DC CONVERTER MODULE (OPTIONAL FOR A10 ONLY) The DC converter module allows the A10 gate operator to function from a 12V battery in the absence of AC mains.
Page 18
7. Reconnect the battery. 8. Reconnect the mains. Upon reconnecting, if the converter module fails to function correctly in the event of a power failure, refer to an installer or service technician. 18 - Centurion Sliding Gate Operators User Guide...
If the gate reaches the fully open position without the beam being activated the gate will close immediately. Centurion Sliding Gate Operators User Guide - 19...
Basic Maintenance CENTURION operators are designed to be maintenance free. However, there are some basic checks that should be carried out regularly, (every six months). These will increase the long term reliability of the system, and obviate false triggering of the protection systems leading to erratic operation of the gate.
POWER SUPPLY All Centurion/FAAC operators have power supplies separate to the controllers. In the case of product malfunction, the power supply fuses should be checked. A10 models are supplied with spare fuses housed in the controller card cover. The FAAC 844 houses spare fuses inside the lid.
The A10 inverter module should be installed and maintained by a qualified installer. FUSE (1) 5A FAST BLOW FUSE (2) 50mA SLOW BLOW FUSE (3) 3A FAST BLOW TIMER CONTROLLED SWITCH FOR COURTESY LIGHT MAINS IN POWER ON INDICATOR Centurion Sliding Gate Operators User Guide - 23...
-10° to +50°C Housing protection IP55 IP55 CP80 CP80 Control card * Corrosion protection (baseplate) Zincroshield Zincroshield Mass of unit (packed) including 7,5Ah Battery 12kg 13.5kg * D3 and D5 have different micro-controller versions 24 - Centurion Sliding Gate Operators User Guide...
IEC 60355-1:1991 & Am1: 1994 & Am2: 1999 IEC 1000-6-3 & IEC 1000-6-1: Generic Emission and Immunity Signed at North Riding, South Africa on 15 August, 2005 Ian Rozowsky Research & Development Director 28 - Centurion Sliding Gate Operators User Guide...
Standard speed + 30% Standard speed + 60% Standard speed + 90% CLOSING SPRINT MODE SELECT: Standard speed Standard Standard speed + 30% Standard speed + 60% Standard speed + 90% Continue on overleaf Centurion Sliding Gate Operators User Guide - 29...
Page 30
The following checks must be made in addition to the above checks to ensure a CE compliant installation: P36 PASSIVE EDGES FITTED TO ALL HAZARDOUS EDGES D3 OPERATOR INSTALLED, WITH CE CHIP FITTED TO CONTROLLER COLLISION SENSITIVITY (see above) SET TO HIGH OR MEDIUM 30 - Centurion Sliding Gate Operators User Guide...
Page 32
CENTURION THE AUTOMATIC CHOICE CENTURION SYSTEMS (PTY) LTD HEAD OFFICE: TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669 148 EPSOM AVENUE, NORTH RIDING P .O. BOX 506, CRAMERVIEW, 2060 SOUTH AFRICA WEB: http://www.centsys.co.za General information e-mail: info@centsys.co.za FOR TECHNICAL SUPPORT CONTACT: SOUTH AFRICA EAST RAND.