Before attempting any work on the system, cut electrical power and disconnect the batteries. 22. Centurion Systems does not accept any liability caused by improper use of the product, or for use other than that 10. The mains power supply of the automated system must for which the automated system was intended.
The Vector electronic controller utilizes the same proven surge protection philosophy that is used in all Centurion products. While this does not guarantee that the unit will not be damaged in the event of a lightning strike or power surge, it greatly reduces the likelihood of such damage occurring. The earth return for the surge protection is provided via the mains power supply earth.
Package Contents Package Contents For standard V400 and V500 operators (VEC40000V2 & VEC50000V2) Item Description Qty. Part No. Vector gate operator (Complete assembly) VEC40000V2 Wall bracket (standard) 1050M20000 Wall bracket pin 1050M36002 Gate Bracket 1050M27000 Gate bracket pin 1050M26002 Origin body 1050M0161M Gate operator keys GTKEYTG01...
Page 10
Control box including charger & controller (Domestic) VECCAD00V2 / (Light Industrial) VECCAD01V2 7 . 5 Item Description Domestic Light Ind Vector Control Card Version 2 built in Rx VECC-D00V2 VECC-D01V2 CP84E Charger CP84E V2 CP84SM2A1E Wall box Misc parts Misc parts User Guide DOC1050D01 DOC1050D01...
Site Considerations Site Considerations In order to ensure a reliable and durable installation thought should be given to: Strength of the pillar For reliable operation it is important to ensure that the way the operator is secured to the wall takes into account the strength of the pillar, the size of the gate, and how frequently the gate would be used: High security kit together with a...
Strength of the gate and gate bracket The gate adaptor kit both strengthens the connection to the gate, and also allows for more flexibility when mounting the bracket to the gate: Welding Through bolts Through bolts Welding Gate adaptor kit Gate adaptor kit (High tensile) BEST...
Install the gate operator only if: It will not pose a hazard to the public. There is sufficient clearance to a roadway and/or public thoroughfares. The installation will meet all municipal and/or local authority requirements once completed. The gate mass, length and application is within the operator specifications (see page 8). The wind loading specifications are not exceeded (see page 42).
Screened cable is always recommended to provide better protection against lightning - earth one end of screening. Domestic charger only. For optimum range an external receiver can be mounted on the wall. ¥ Centurion has available custom VECTOR cable order reference: CABLEVEC68 Figure 6 Cabling Requirements Page 17...
Operator Installation Operator Installation 1. Determine gate opening angle and direction of operator (inward or outward). CLOSED Alternatively the swing angle can be deter- mined more accurately with the process detailed on page 45. 120° 60° 70° 110° 100° 90° 80° 2.
4. Secure the bracket to the wall with the most appropriate means. It is critical that the wall bracket is securely mounted. See page 14 for site considerations. Determine the gate bracket position Start with the operator fully retracted. Turn out the actuator tube one or two turns. 5.
Page 20
Unlock the operator and swing the gate closed. 9. Remove the pin and the operator from the bracket, check that there are at least one or two turns of the actuator before it is fully extended. If it becomes obvious that the operator does not have enough stroke, reduce either the A or B distances by moving the wall bracket.
12. Fit operator, gate bracket pins and snap rings As an alternative to the snap ring, fit a padlock. Adjust origin clamp (NB - Not required for outward swinging gates) 13.Unlock the operator and open the gate fully. 14. Slide the origin clamp along the actuator tube, right up to the operator.
Operator Installation Operator Installation Inward Swing Gate Setup G A T E C L O S E D For gates opening 90° or less: For gates opening more than 90°: For best security (but slower operation) install with large B value For fast operation (but less security) install with small A and small B values CAUTION:...
Page 23
For V400 (400mm operator) 1400mm Extended 1400mm Extended 0° Gate opening angle 1000mm Retracted 1000mm Retracted Recommended positions (Only for a 2.5m gate or shorter) Gate swing A value B value angle 90° or less 120° 60° 100° 70° 110° 110°...
Outward Swing Gate Setup CAUTION: For gates opening 90° or less: Dimension A is always measured at right angles to the centre-line of the gate in its open position. Outward opening swing gates must have physical end stops fitted in the open position.
Page 25
For V400 (400mm operator) 1400mm Extended 1400mm Extended 0° Gate opening angle 1000mm Retracted 1000mm Retracted Recommended positions (Only for a 2.5m gate or shorter) Gate swing A value B value angle 90° or less 100° 120° 110° 60° 120° 70°...
Electrical Set-up Electrical Set-up WARNING 1. Always check that the isolator in the mains supply to the gate is in the OFF position, before doing any work. 2. Ensure that all low voltage systems (Less than 42.4V) are suitably protected from damage, by disconnecting all sources of power such as chargers and batteries before doing any work.
4. Check that the charger and battery are connected to the controller. Ensure the battery polarity is correct. Aux 12V Com Saf Light Light 5. Switch on the mains supply (via isolator). Batt + Batt - 6. Ensure that both the controller and charger are MTR M+ MTR M - effectively earthed for improved lightning...
How to set up additional features How to set up additional features on the Vector Controller on the Vector Controller Figure 10 provides the full menu of features that can be set up on the system. Explanation of each Figure 10 provides the full menu of features that can be set up on the system. Explanation of each feature is provided in the section “CONTROLLER FEATURES”.
Controller Features Controller Features § Refer to Table 1 on page 39 for Schedule of Factory Defaults for each feature described below. SAFETY (COLLISION FORCE) - MENU 2 MTRM/S COLLISION FORCE If the gate is obstructed, the internal collision circuitry will activate. The response of the system to a collision will vary, depending on the Operating Standard (eg CE, UL325) selected.
Page 32
AUTO-CLOSE ON OPEN - will automatically close the gate if it has reached the fully open. AUTO-CLOSE ON PARTLY OPEN - will automatically close the gate if it is stopped while opening, but before the reaching the fully opened position. AUTO-CLOSE ON PARTLY CLOSED - will automatically close the gate if it is stopped while closing, but before reaching the fully closed position.
Page 33
closed position and via the PCM, push the two Mechanical lip gates into the fully closed position, but not past. S Gate closes first SHORT STOP VALUE M gate closes The short stop distance can be set between 1mm slightly behind and 40mm of piston stroke.
Page 34
RAMP DOWN DISTANCE Sets the ramp-down distance in millimeters of travel of the piston when stopping. This setting applies to both motors. CRAWL DISTANCE Sets the final crawl distance in millimeters of travel of the piston when reaching an endpoint. This setting applies to both motors. PUSH FORCE LIMIT Sets the maximum push force delivered by the motors.
Page 35
Outside closing beam IRBO=IRBC Configures the opening beam to act as a closing beam while the gates are closing. This allows one set of beams to be used across the line of the driveway up to where the gates open. IR BEAM ALARMS Inside closing beam While the gates are fully closed, this feature allows the...
Page 36
PEDESTRIAN OPENING – MENU 7 This feature is associated with the PED input on the controller. When activating this input, the system will open one of the gates (selectable in a double swing gate installation) to the pedestrian open position, and then automatically close after the pedestrian auto-close time lapses. The gate will open only after the adjustable pre-opening delay time.
Page 37
It can also be turned on for the same timed period by momentarily connecting the LIT input to COM.(eg activating a pushbutton connected to these terminals) Via the same pushbutton connected across LIT and COM, it can also be turned ON permanently by application of an impulse longer than 3 seconds.
Page 38
REMOTE CONTROLS – MENU 11 The controller is capable of learning up to 64 Centurion Nova remote controls / transmitters. Each transmitter can have up to 4 buttons. Each transmitter learned into the system is assigned a unique transmitter ID.
Factory Defaults Schedule Factory Defaults Schedule South African Standard Profile UNIT DEFAULT PARAMETER DESCRIPTION YES/NO Auto-Close Enabled Auto-Close from Fully Open YES/NO Auto-Close from Partly Open YES/NO Auto-Close from Partly Closed YES/NO Auto-Close Time mm:ss 00:00* 0:15 04:00* Auto-Close Override Time Mode of Operation S,R,C Standard...
Page 40
South African Standard Profile Continue UNIT DEFAULT PARAMETER DESCRIPTION % (Full Open) PED Open Distance PED Auto-Close Time PED Pre-Open Delay Time PED Pre-Close Delay Time Gate Lock Enabled YES/NO Gate Lock Type Striker Gate Lock Pre-Release Time 24.0* 0.1* Gate Lock Release Time 0.1* 24.0*...
Description of Terminal Functions Description of Terminal Functions S Sens1 Motor S (MTR S) operator . Connects to the thin PURPLE wire of the Motor S operator. S Sens2 Motor S (MTR S)operator. Connects to the thin BLUE or ORANGE wire of the Motor S operator.
Page 42
External gate status indicator. (A low current output signal.) An output terminal which provides a low current, drive (approx. 4,5V DC, 20mA) to a LED which can be used to indicate the gate status remotely. If more than 3 LED's are required it is necessary to fit the CP78 MULTI LED driver card.
LED Indicator Lights LED Indicator Lights The controller is fitted with diagnostic lights (LEDs) that assist with the set-up and maintenance of the gate. Table 2 below provides a description and purpose of the indicator lights with figure 11 alongside, indicating the location on the control During Normal Operation S Sens2...
Charger and Pillar Light Connections Charger and Pillar Light Connections S Sens1 S Sens2 M Sens1 M Sens2 Sens+ Sens- Safe CLS Safe OPN LCK/STP 220V AC Auxiliary supply Mains in Pillar light Aux 12V NEUTRAL Safe Com Protection fuse on Light mains input to Light...
Determine Gate Swing Angle Determine Gate Swing Angle Use this procedure to accurately determine the gate opening angle: Step 1 Close the gate and measure a distance of 1m from the centreline of the gate hinge. Make a mark on the ground. Step 2 Open the gate and measure a distance along the gate a...
Wiring Diagram for MOTOR M Wiring Diagram for MOTOR M (MTR M) Operator (MTR M) Operator S Sens1 MASTER S Sens2 PURPLE PURPLE THIN PURPLE M Sens1 THIN BLUE / ORANGE BLUE BLUE M Sens2 THIN RED / GREY Sens+ THIN BLACK Sens- BLACK...
Wiring Diagram for MOTOR S Wiring Diagram for MOTOR S (MTR S) Operator (MTR S) Operator S Sens1 PURPLE PURPLE THIN PURPLE S Sens1 S Sens2 BLUE BLUE THIN BLUE / ORANGE S Sens2 M Sens1 PURPLE PURPLE M Sens1 M Sense2 BLUE BLUE...
Wiring Diagram for Safety Beams Wiring Diagram for Safety Beams (for CE compliance) (for CE compliance) CLOSING OPENING BEAM BEAM - 12V/24V - 12V/24V +12V/24V +12V/24V Figure 15. Wiring diagram for safeties Page 48...
Page 49
S Sens1 S Sens2 M Sens1 M Sens2 Sens+ Sens- Safe CLS Safe OPN LCK/STP Aux 12V Safe Com Light Light Batt + Batt - MTR M+ MTR M - MTR S+ MTR S - Page 49...
Wiring diagram for other inputs Wiring diagram for other inputs +12V +12V/24V REMOTE CONTROL CIRCUITRY FREE EXIT CIRCUITRY HOLIDAY LOCKOUT PEDESTRIAN PILLAR LIGHT STATUS KEYSWITCH KEYSWITCH PUSHBUTTON (normally CLOSED) (normally OPEN) (normally OPEN) SOLENOID Only applicable if external radio receiver is being used Figure 16.
Page 51
S Sens1 S Sens2 M Sens1 M Sens2 Sens+ Sens- Safe CLS Safe OPN LCK/STP Aux 12V Safe Com Light Light Batt + Batt - MTR M+ MTR M - MTR S+ MTR S - SOLENOID OR STRIKE LOCK Page 51...
Allowable Wind Loading Allowable Wind Loading Wind speeds for which operator will still operate the gate (for V400 or V500 operators) For a 25% covered gate: (Palisades, etc.) x 1.8m high Value of Gate lengths: A or B dimension Up to Up to Up to Up to...
10.Centurion Systems (Pty) Ltd does not accept any liability caused by improper use, of the product, or for use other than that for which the automated system was designed.
Page 56
Centurion Systems (Pty) Ltd Head Office: Tel: +27 (0)11-699-2400, Fax: +27 (0)11-704-3412 or (0)11-462-6669 (Omit (0) when dialing from outside South Africa) 148 Epsom Avenue, North Riding P.O. Box 506, Cramerview, 2060 South Africa Sharecall 0860-CENTURION (Sharecall number applicable when dialed from within South Africa only) or visit www.centsys.co.za...