2.
Highlight Software Management and press Enter.
3.
Highlight SNMP and press Enter.
4.
Highlight Trap Sinks and press Enter.
5.
Highlight Create New Trap Sink and press Enter
6.
Highlight Trap Sink IP address and press the backspace key to erase the
current value, then type the new IP address in this field.
7.
Highlight Trap Filter and press the spacebar to toggle through the severity
levels.
See Table 3 on page 233.
8.
Press Ctrl-A to save the Trap Sink.
Deleting a Trap Sink
To delete a trap sink:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight Software Management and press Enter.
3.
Highlight SNMP and press Enter.
4.
Highlight Trap Sinks and press Enter.
5.
Highlight the trap sink you want to delete and press the spacebar to mark it.
The mark is an asterisk (*) to the left of the listing.
6.
Highlight Delete Marked Entries and press Enter.
Table 3 Event severity levels
Level
Fatal
Critical
Major
Minor
Warning
Information Information only, no action is required
Making CIM Settings
By default, Common Information Model (CIM) service is set to Automatic and its
normal status is Started.
Non-Recoverable error or failure has occurred
Action is needed now and the implications of the condition are
serious
Action is needed now
Action is needed but the condition is not a serious at this time
User can decide whether or not action is required
Chapter 5: Management with the CLU
Meaning
233