Making UPS Settings
These settings control how the VTrak subsystem detects the UPS unit and
responds to data reported by the UPS unit.
To make UPS settings:
1.
Click the Subsystem
2.
Click the UPS
3.
Click the Settings tab in Management View.
4.
Perform the following actions as required:
•
Verify the Current UPS Communication method. See Note 1:
•
•
•
•
Choose a Detection Setting from the dropdown menu:
•
•
•
•
Type values into the Threshold fields. See Note 2:
•
•
•
•
•
For UPS units with network cards, type the IP addresses or DNS names
in fields UPS 1 and UPS 2. See Note 4.
5.
Click the Submit button to apply your settings.
Note 1: VTrak supports multiple UPS units using network or serial
connections, but not a combination of both methods.
Note 2: Detection Setting must be set to Auto. If a UPS is detected, the
setting changes to Enable.
Note 3: The maximum recommended Loading Ratio varies among models of
UPS units. The general range is 60% to 80%.
icon in Tree View.
icon.
SNMP – Network connection.
Serial – Serial connection.
Unknown – No connection.
Automatic – Default. If a UPS is detected when the subsystem
boots, the setting changes to Enable.
Enable – Monitors UPS. Settings changes, reports warnings, and
logs events.
Disable – Monitors UPS only.
Runtime Remaining Threshold – Actual time below this value
resets adaptive writeback cache to writethrough.
Warning Temperature Threshold – Actual temperature above this
value triggers a warning and logs an event.
Loading Ratio Threshold – Actual loading ratio (percentage)
above this threshold triggers a warning and logs an event. See
Note 3.
Battery Charge Remaining Threshold – Reserve capacity below
this percentage triggers a warning and logs an event.