VTrak E-Class Product Manual
4.
Press Y to continue.
The screen will display shutdown and startup functions.
5.
When the
Restarting – RAID with JBOD Expansion, Serial
To restart multiple subsystems:
1.
From the Main Menu, highlight Additional Info and Management, and press
Enter.
2.
Highlight Shutdown or Restart and press Enter.
3.
Press the spacebar to display Shutdown then press Enter.
A warning message appears.
4.
Press Y to continue.
The screen displays shutdown functions.
5.
If you have other VTrak RAID Subsystems, repeat the same procedure for
each of them.
6.
Wait for two to three minutes, then turn off the power switches for all
subsystems.
7.
Wait 30 seconds, then turn on the power switches on all JBOD
subsystems.
8.
Wait 30 more seconds, then turn on the power switches on the RAID
subsystem.
9.
When the
again.
prompt appears, log into the CLU again.
Login:
Do not restart the VTraks during a firmware upgrade procedure.
Wait until the upgrade is one and you are prompted to restart.
Login:
prompt for the Head Unit appears, log into the CLU
Warning
258