Mobotix D12 Manuals page 45

D12 camera
Hide thumbs Also See for D12:
Table of Contents

Advertisement

D12 Camera Manual Part 1
(1) Remove the dome
Take a cotton cloth and remove the transpar-
ent dome by turning it in counter-clockwise
direction.
(2) Insert the lens units and mount the central
lens screw
Remove the center lock screw and the
washer. Insert the lens units into the seatings.
Insert the lock screw with a washer into the
center of the camera and gently tighten it to
hold the lens units in place.
Caution: Avoid over-tightening the screw as
this might damage the camera housing.
(3) Connect the ribbon cables to the lens units
Connect the ribbon cables marked
according to the Image Sensor Combination
table (opposite page) to the installed lens
units.
Example:
A
D12D-Night
ribbon cable on the
ribbon cable is always connected to the
(color) lens mount (see Image Sensor Combi-
nation table on the opposite page).
While doing so, make sure that the lens unit's ribbon cable connectors are
always pointing upwards into the dome. This will ensure that the lenses
can be positioned freely later on, without putting any strain on the ribbon ca-
bles. Make sure that the ribbon cables are running properly along the inside
of the dome's rim. The ribbon cables must not obstruct the line of vision of
the lenses!
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
L
and
R
always takes the
L
(BW) lens mount, the
R
43
/124
Dismount the dome by
turning it
counter-clock-
wise

Advertisement