Chapter 3
General Settings
3.1

Powering On

3.1.3
Powering On
This section explains how to turn on the ETERNUS DX.
The following methods can be used to turn the power on:
Via the power switch
Press the Power switch to turn on the ETERNUS DX.
The following methods can be used to turn the power on by linking with the server.
Via the power synchronized unit
Use the power synchronized unit to turn on the ETERNUS DX.
Via the Wake On LAN function
Use the Wake On LAN function to turn on the power.
Before turning on the ETERNUS DX, make sure that the main line switches of the power distribution units
and the PSU switches on the power supply units of the ETERNUS DX are "ON". Do not turn the main line
switches of the power distribution units and the PSU switches on the ETERNUS DX to the OFF position.
After turning the power on, it takes approximately three minutes (approximately six minutes in a Uni-
fied configuration) for the ETERNUS DX to become READY (i.e. the READY LED (
error is detected in a component during the initial power-on diagnostics, it may take up to ten minutes
for the ETERNUS DX to be in a READY state. This should be taken into consideration for scheduled opera-
tions.
Before turning the server on, check that the ETERNUS DX and the network devices that connect the
ETERNUS DX and the server are all in READY status.
If the server is turned on while any of these devices are not in READY status, the server may not be able
to recognize the ETERNUS DX.
To turn on the ETERNUS DX by linking with the server, the server must wait until the ETERNUS DX is in a
READY state.
If the Auto Power function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is automat-
ically turned on when power is supplied to the ETERNUS DX.
If the Power Resume function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is auto-
matically turned on after the power is restored.
If the REMOTE LED (
ized unit.
After power-off, wait for about one minute before turning power on again.
This section explains how to use the Power switch to turn on the ETERNUS DX.
For other procedures, refer to the related manuals.
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Configuration Guide (Basic)
) of the ETERNUS DX is green, turn on the ETERNUS DX via a power synchron-
38
Copyright 2014 FUJITSU LIMITED
) turns on). If an
P3AM-7732-05ENZ0