Frequency setting by external terminals
4.6.3

Input compensation of multi-speed and remote setting (Pr. 28)

By inputting the frequency setting compensation signal (terminal 1, 2), the speed (frequency) can be
compensated for relative to the multi-speed setting or the speed setting by remote setting function.
Parameter
Number
Multi-speed input
28
compensation selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 175)
REMARKS
⋅ Select the compensation input voltage (0 to ±5V, 0 to ±10V) and used terminal (terminal 1, 2) using Pr. 73 Analog input
selection.
♦ Parameters referred to ♦
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239 (multi-speed operation)
Pr. 73 Analog input selection
Pr. 59 Remote function selection
92
Name
Initial Value
Refer to page 160
Refer to page 93
Setting Range
0
0
1
Refer to page 88
Description
Without compensation