Mitsubishi Electric FR-F720-0.75K to 110K Instruction Manual page 216

Table of Contents

Advertisement

List of calibration parameters
Para
Name
meter
C2
Terminal 2 frequency
(902)
setting bias frequency
C3
Terminal 2 frequency
(902)
setting bias
125
Terminal 2 frequency
(903)
setting gain frquency
C4
Terminal 2 frequency
(903)
setting gain
C5
Terminal 4 frequency
(904)
setting bias frequency
C6
Terminal 4 frequency
(904)
setting bias
126
Terminal 4 frequency
(905)
setting gain frequency
C7
Terminal 4 frequency
(905)
setting gain
[Special monitor selection No.]
Refer to page 131 for details of the monitor description.
Data
Description
H01
Output frequency/speed
H02
Output current
H03
Output voltage
Frequency setting value/speed
H05
setting
*4
H06
Running speed
H08
Converter output voltage
H09
Regenerative brake duty
Electronic thermal relay function
H0A
load factor
H0B Output current peak value
H0C Converter output voltage peak value
H0D Input power
*1
Input terminal monitor details
b15
*2
Output terminal monitor details
b15
*3
The setting depends on capacities. (55K or less/75K or more)
*4
When Pr.37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 130)
[Fault data]
Refer to page 259 for details of fault description.
Data
Description
Data
H00
No fault
H50
H10
OC1
H51
H11
OC2
H52
H12
OC3
H60
H20
OV1
H70
H21
OV2
H80
H22
OV3
H81
H30
THT
H90
H31
THM
H91
H40
FIN
HA0
Instruction code
Read
Write
Extended
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
Unit
0.01Hz/1
*4
0.01A/0.1A
*3
0.1V
0.01Hz/1
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
*3
0.1V
0.01kW/
0.1kW
*3
CS
RES
STOP
MRS
Description
Data
Description
IPF
HA1
OP1
UVT
HB0
PE
ILF
HB1
PUE
OLT
HB2
RET
BE
HB3
PE2
GF
HC0
CPU
LF
HC1
CTE
OHT
HC2
P24
PTC
HC4
CDO
OPT
HC5
IOH
Communication operation and setting
Para
Name
meter
C42
PID display bias coefficient
(934)
C43
PID display bias analog
(934)
value
C44
PID display gain coefficient
(935)
C45
PID display gain analog
(935)
value
Data
Description
H0E Output power
H0F
Input terminal status
H10
Output terminal status
H11
Load meter
H14
Cumulative energization time
H17
Actual operation time
H18
Motor load factor
H19
Cumulative power
H32
Power saving effect
H33
Cumulative saving power
H34
PID set point
H35
PID measured value
H36
PID deviation
JOG
RH
RM
ABC2
ABC1
Data
Description
HC6
SER
HC7
AIE
HE6
PID
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13
Instruction code
Read
Write
22
A2
22
A2
23
A3
23
A3
Unit
0.01kW/
0.1kW
*3
*1
*2
0.1%
1h
1h
0.1%
1kWh
Variable
Variable
0.1%
0.1%
0.1%
RL
RT
AU
STR
FU
OL
IPF
SU
Fault description display example
(instruction code H74)
For read data H30A0
(Previous fault ...... THT)
(Latest fault ...... OPT)
b15
b8 b7
0
0
1
1 0 0 0 0
1
0
1
0
0
Previous fault
Latest fault
(H30)
(HA0)
Extended
9
9
9
9
b0
STF
b0
RUN
4
b0
0
0
0
207