4.11.3 Input compensation of multi-speed and remote setting (Pr. 28)

By inputting the frequency setting compensation signal (terminal 1, 2), the speed (frequency) can be compensated
for relative to the multi-speed setting or the speed setting by remote setting function.
Parameter
Name
Number
Multi-speed input
28
compensation selection
REMARKS
⋅ Select the terminal (terminal 1, 2) used for compensation input voltage (0 to ±5V, 0 to ±10) using Pr. 73 Analog input selection.
⋅ When using terminal 1 for compensation input, set "0" (initial value) in Pr. 868 Terminal 1 function assignment.
♦ Parameters referred to ♦
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239 (multi-speed operation)
Pr. 73 Analog input selection
Pr. 59 Remote function selection
Pr. 868 Terminal 1 function assignment

4.11.4 Remote setting function (Pr. 59)

Even if the operation panel is located away from the enclosure, you can use contact signals to perform
continuous variable-speed operation, without using analog signals.
By merely setting this parameter, you can use the acceleration, deceleration and setting clear functions of the
motorized speed setter (FR-FK).
Parameter
Name
Number
59
Remote function selection
Inverter
Forward
rotation
STF
Acceleration
RH
Deceleration
RM
10
Clear
RL
2
SD
5
Connection
diagram for remote setting
(1) Remote setting function
⋅ Use Pr. 59 to select whether the remote setting function is used or not and whether the frequency setting storage
function in the remote setting mode is used or not.
When Pr. 59 is set to any of "1 to 3" (remote setting function valid), the functions of the RH, RM and RL signals are
changed to acceleration (RH), deceleration (RM) and clear (RL).
⋅ When the remote function is used, the output frequency of the inverter can be compensated for as follows:
External operation ... Frequency set by RH/RM operation + external running frequency or PU running frequency
(other than multi-speed).
(When making analog input compensation, set "1" in Pr. 28 Multi-speed input compensation
selection.
When Pr. 28 is set to "0" and acceleration/deceleration is made to reach the set frequency of
the analog voltage input (terminal 2 or terminal 4) by RH/RM, the auxiliary input by terminal 1
becomes invalid.)
PU operation ............. Frequency set by RH/RM operation + PU running frequency
Initial Value
0
Refer to page 274
Refer to page 165
Refer to page 273
Initial Value Setting Range
0
*
0Hz
ON
Acceleration
ON
(RH)
Deceleration
(RM)
Clear (RL)
Forward
ON
rotation (STF)
Power supply
* External operation frequency (other than multi-speed) or PU running frequency
Frequency setting by external terminals
Setting Range
0
Without compensation
1
With compensation
Refer to page 161
RH, RM, RL signal
function
0
Multi-speed setting
1
Remote setting
2
Remote setting
3
Remote setting
When Pr. 59 = 1, 2
When Pr. 59 = 3
ON
ON
ON
ON
Description
Description
Frequency setting
storage function
Yes
No
No
(Turning STF/STR off
clears remotely- set
frequency.)
When Pr. 59 = 1
When Pr. 59 = 2, 3
Time
ON
ON
ON
ON
165
Pr.27
page 161
Pr. 29
page 171
Pr. 58
page 253
Pr. 60
page 265
4