Input Compensation Of Multi-Speed And Remote Setting (Pr. 28) - Mitsubishi Electric F700 Instruction Manual

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

Frequency setting by external terminals
4.6.3

Input compensation of multi-speed and remote setting (Pr. 28)

By inputting the frequency setting compensation signal (terminal 1, 2), the speed (frequency) can be
compensated for relative to the multi-speed setting or the speed setting by remote setting function.
Parameter
Number
Multi-speed input
28
compensation selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 156)
REMARKS
⋅ Select the compensation input voltage (0 to ±5V, 0 to ±10V) and used terminal (terminal 1, 2) using Pr. 73 Analog input
selection.
♦ Parameters referred to ♦
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239 (multi-speed operation)
Pr. 73 Analog input selection
Pr. 59 Remote function selection
88
Name
Initial Value
Refer to page 143
Refer to page 89
Setting Range
0
0
1
Refer to page 84
Description
Without compensation
With compensation